Digital Inputs and Outputs Timing Table
Sensor
Digital Input
to FPGA
Digital Input to
Sensor (Trigger)
Trigger (Digital
Input) to Strobe
Strobe (Sensor)
to Digital Output
Trigger (Digital Input) to
Strobe (Digital Output)
Trigger (Digital Input) to
start of exposure
MT9P031
45 nS
100 nS
230 nS
72 nS
308 nS
2 μS
MT9V034
45 nS
100 nS
11 μS
72 nS
11 μS
11 μS
EV76C56 mode 01-96
45 nS
100 nS
18.62 μS
72nS
18.63 μS
42 μS
EV76C56 mode 23-114
45 nS
100 nS
18.62 μS
72 nS
18.63 μS
31μS
Please see the CURRERA-R Quick start guide to learn more about the available trigger modes and their selection.