8th.Function and usage 

 
1. On/off button: If it is not turned on, press and hold the “On/Off button” to display the sensitivity value; if it is 

turned on, press and hold the 

“On/Off button” to shut down. 

2. "+" "-" key: Press the sensitivity "+" or "-" to adjust the sensitivity to a suitable value. When there is no liquid 

at the position to be detected, the buzzer will sound. Press the "+" and "-" keys to adjust the sensitivity 

appropriately to achieve more precision. 

3. Indicator light: the blue light is on when the liquid is detected, and the buzzer sounds. The blue light goes 

out after leaving the test target. When the battery is low, the red light flashes once every 2 seconds. 

4. Output protection: When the OUT terminal of the output port is directly connected to a voltage of 5-24V, it 

will automatically be forced to shut down. 

5. Digital tube display: sensitivity adjustment range 1-100. When the battery voltage is lower than half, the 

digital tube will automatically reduce the brightness to save power consumption. 

6. Automatic shutdown: automatic shutdown after 5 minutes when unmanned operation "+" "-" or no induction, 

to avoid forgetting to shutdown after use and running out of power. 

7. Liquid detection: move down from the top of the container for detection. When liquid is detected, the blue 

indicator light will be on and the buzzer will alarm

 

 

9th.Detection steps 

 

Summary of Contents for XKC-E700

Page 1: ...rict Shenzhen 1 9 Handheld liquid level detector XKC E700 operating instruction Without putting it inside the container The height or position of the liquid can be detected outside the container Phone...

Page 2: ...liquid inside the container Or location Simple operation classic applications such as detecting the height or position of various toxic substances strong acids strong alkalis and various liquids in hi...

Page 3: ...tector When the liquid level slowly rises and approaches the detector the parasitic capacitance of the liquid will be coupled to this static capacitance making the capacitance value of the detector la...

Page 4: ...y is less than 10mPaS it is measured normally 10mPaS dynamic viscosity 30mPaS may affect the detection When the dynamic viscosity is greater than 30mPaS it cannot be measured because a large amount of...

Page 5: ...e light is on when the liquid is detected and the buzzer sounds The blue light goes out after leaving the test target When the battery is low the red light flashes once every 2 seconds 4 Output protec...

Page 6: ...on and the high position of the liquid plane is detected Wall thickness and sensitivity Test material is acrylic Wall thickness sensitivity reference value Wall thickness 1mm Sensitivity value 20 Wall...

Page 7: ...o not turn on please confirm whether the battery voltage is normal and whether the battery is installed correctly 6 Please do not disassemble the product privately If you have any comments or suggesti...

Page 8: ...repair modification external power supply damage and other abnormal damage 2 Damage caused by incorrect installation and use of the product by the user not following the requirements of the manual 3...

Page 9: ...rt to provide accurate information in this manual However Xingkechuang does not guarantee that the contents of the manual are completely free of errors All statements information and suggestions in th...

Reviews: