XKC-Y27B-D3
XKC-Y27B-D4
XKC-Y27B-D6
XKC-Y27B-D8
XKC-Y27B-D10
13th.Precautions
1. The viscosity of the liquid medium to be measured
Normal measurement when dynamic viscosity <10mPaS. 10mPaS < dynamic viscosity < 30mPaS may affect the
detection. When the dynamic viscosity is more than 30mPaS, it cannot be measured because a large amount of liquid
adheres to the wall of the container.
2. Note: As the temperature increases, the viscosity decreases, and most high-viscosity liquids are more affected by
temperature, so pay attention to the effect of liquid temperature when measuring viscous liquids.
3. Pay attention to keep the level gauge clean, try to prevent corrosion and avoid violent collisions and blows from other
objects.
4. When installing outdoors, avoid direct sunlight on the main body of the level gauge, keep away from heat sources and
pay attention to ventilation. If the ambient temperature exceeds the rated temperature, corresponding cooling protection