7.5 Overloading
The machine is equipped with an overload protection function on the inverter. When
the machine is overloaded, the overload error will be showed on the display of the control
panel. In this case, just disconnect the power plug and decrease the loading , then restart it.
7.6 Maintenance
Any repairs must be performed by Xingyi Service Center training service personnel and
use original Xingyi accessories. If your machine needs repair, please contact with your retailer.
8.
Frequently Asked Questions and Solutions
This chapter describes some of the possible failures and how to handle them. If you still
can not resolve or have an error, please contact your nearest retailer.
Problem
Possible reason
Solution
The machine can’t run.
Emergency stop switch is pressed
Turn on the emergency stop switch
Overload
Unplug the power cord and taking decreasing
loading measures,then plug it in again.
Power and power cable damage
Contact a licensed electrician
The machine uttered a
low buzz when turn on
Dust in the motor impeller
Clean the dust
Motor burned down
Replace the motor
Input power Phase loss .
Turn off the machine power to avoid burning
the motor,and correct the power source
The machine is difficult
to hold or the motor
current consumption is
large
There are not enough diamonds pads
under the device or using wrong
diamonds
Use the number of diamonds recommended by
Xingyi to reduce workforce on the grinder and
operator