![background image](http://html.mh-extra.com/html/xingyue/xy260t-4/xy260t-4_service-manual_3399105010.webp)
2-2 MAINTENANCE AND TUNE-UP PROCEDURE
This section describes the servicing procedures for each items of the periodic maintenance
requirments.
BATTERY
Inspect every 3000 km (6 months)
The battery must be removed to check the
electrolyte lecel and specific gravity.
Remove the battery
○
一
and
○
+
leads at the
battery terminals.
Remove the battery from the frame.
Check electrolyte for level and specific
gravity. Add distilled water, as necessary,
to keep the surface of eletrolyte above MIN.
level line but not above the MAX. level line.
For checking specific gravity, use a hydrometer
to determin the charged condition.the standard
specific gravity is 1.28 at 20
℃
for 12V type.
- 7 -