XD-4GBOX-ED
S1
S2
S3
S4
Function
ON
OFF
-
-
Configuration mode
OFF
OFF
-
-
Running mode
-
-
-
ON
Factory mode (V2.0.0 and up)
-
ON
-
-
Factory mode (V1.1.4 and up)
Other
Undefined
4GBOX
S1
S2
S3
S4
Function
OFF
-
-
-
Running mode
ON
-
-
-
Configuration mode (please power on again)
-
OFF
-
-
Modbus RTU
-
ON
-
-
X-NET mode (V2.0.0 and up)
other
Undefined
Note:
4GBOX v2.0.0 and up supports Modbus RTU and X-NET mode. Version 1.1.4 and down
only supports X-NET mode. The switch S2 ON is factory mode, please turn if off for normal
using.
4GBOX-M (only for V1.1.2 and down version)
S1
S2
S3
S4
Function
OFF
OFF
-
-
Running mode
ON
OFF
-
-
back to default serial port parameters
when power on again
-
ON
-
-
Configuration mode (power on again)
Other
Note: after setting the serial port connection flag, SIM card, signal strength of 4GBOX-M, if it
needs to set them again, please turn on switch 2 and power on again.
2-8. Initialization time
The module initialization time is depend on the telecom operator. The table shows the time of
Chinese telecom operators:
Telecom operator
Initialization time (s)
China mobile
21.31
China unicom
23.24
China telecom
59.89
Summary of Contents for 4GBOX