DP-708/DP-5022 series stepper driver
14
temperature is higher
than normal.
ambient temperature.
E-006
Over
Current
Driver output to
motor error or motor
error
Change the damaged motor and
check motor wiring
●
E-007
System
initialize
failure
System IC is
damaged.
Contact Xinje or an authorized
distributor.
●
●
Can not clear the alarm information through digital panel, need re-power.
△
Can clear the alarm information through digital panel after remove the error, no need to
re-power.
Warning information is shown as below:
Warning code
Description
Note
1
Bus voltage is too high
2
Bus voltage is too low
3
Module temperature is too high
4
Temperature detection is abnormal
5
Bus voltage detection is abnormal