level in good condition.
When installing the servo motor vertically up, please pay attention not
to grease the lip of the oil seal.
The stress state of
the cable
Do not "bend" the wire or apply "tension" to it. Especially, the core wire
of the signal wire is 0.2mm or 0.3mm, very thin.
connector
◆
When the connector is connected, please make sure there is no
garbage or metal sheet or other foreign matter in the connector.
◆
When connecting the coupling to the servo motor, it is important to
connect the coupling from the side of the main circuit cable of the servo
motor first, and the ground wire of the main cable must be connected
reliably. If one side of the encoder cable is connected first, the encoder
maybe error due to potential difference between PE.
◆
Please make sure that the pins are aligned correctly when engaged.
◆
The fraud connector is made of resin. Do not impact the connector
to avoid damage.
◆
When handling operations while the cable remains connected, be
sure to hold the servo motor body. If you only hold the cable for
handling, you may damage the connector or break the cable.
◆
If a curved cable is used, full attention shall be paid to the
distribution of the cables and no stress shall be applied to the connector
part. If stress is applied to the connector part, the connector may be
damaged.