Output signal wiring diagram
Optocoupler type
Relay type
Servo drive upper device
COM
SO
X3
COM
0
V
+24
V
Servo drive upper device
+24
V
0
V
COM
X3
SO
COM
Note: max load current 400mA (if control the brake motor by SO signal, please confirm the
brake current, if it is larger than 400mA, please use intermediate relay). 750w and above
power motor is recommended to use intermediate relay.
3-3. Communication port
RS-232 communication
Connect to PC for debugging.
(5-pin port)
Pin no.
Name
Explanation
1
TXD
RS232 send
2
RXD
RS232 receive
3
GND
RS232 ground
Note: please use the cable supplied by XINJE Company
RS-485 communication