V5 series inverter
15
2
Installation and Wiring
2-1. Installation environment
2-1-1. Environment requirement
Ambient tempeature: -10ºC~40ºC. The inverter should be derated when the temperature over 40ºC, at the same time
ventilation and heat dissipation should be enhanced.
Far away from the location with direct sunlight, dust, floating fiber or metal powder.
Mount in the location free of corrosive gas and combustible gas.
Mount in the location free of condensation, and the humidity should less then 95%RH.
Mount in the location where vibration less than 5.9m/s²(0.6G)
Far away from electramagnetism interfere source and other electric instruments sensitive with electramagnetism in-
terfere.
2-1-2. Mounting location and space
Mount the inverter vertically under general condition.
The mounting space and distance are shown in Fig. 2-1.
When several inverters are mounted up and down, air diversion plate should be fixed in the middle as shown in Fig.
2-2.
Fig. 2-1 Mounting Space Fig.2-2 Mounting of Multi-Inverters
2-1-3. Mounting and removing
Removing: Romove the four screws on the cover with phillips screwdriver
Mounting: Allign the mounting holes and then fix the screws.
Air diverting
plate