V5 series inverter
30
Fig. 3-4 Display during initialize, stop and run
2. Parameters displayed in running status
When the inverter receive running command, it starts to enter running status and operation panel will display running mon-
itor parameters, the default parameter is output frequency (b-00),as shown in Fig.3-4 C, the unit indicator on the top right
indicates the unit.
Press key can cycle display parameter in running status (defined by function code P3.41 and P3.42).While display-
ing, press key to shift to the default parameter b-00 (output frequency), Otherwise, the operation panel will dis-
play the last monitor parameter constantly.
3. Alarm information
When then inverter detects error signal, the panel will display error code, the code will flicker to catch your attention as
shown in Fig.3-5; Press key to view the relative error parameters in stopping status, and then press to switch
to error code display.
If you want to view error information, press to view P6 parameter in editing status.After you finding out and solve
the problem, the inverter can be reset by key or control terminals or communication command. The error code will
not disappear until the error is solved.
Note:
For some serious error such as over current, over voltage etc, please do not reset the inverter and run until you solve
the problem, otherwise the inverter may be damaged.
Fig.3-5 Alarming display status
4. Editing status
pressing key to enter editing status in stopping ,running or alarming status (if set password, you should input correct
password to enter, refer to P0.00 and Fig 3-9 for details).This status can be displayed in three classes menu, they are: code
group
→
code No.
→
code parameter, you can enter the sub-menu by pressing .In code parameter status,
press to save parameter and press to exit without saving.
Fig.A
Fig. B
Fig. C
Power on and
initialize, display
the dynamic picture
Stop status, display
the stop parameters
running
status,
display the running
parameters