V5 series inverter
32
Fig. 3-8 Parameter editing
In the third level menu, the parameter can’t be changed if no bit is flashing, the possible reasons are:
(1) The setting of this parameter can not be changed, such as the actural detected parameters or recorded parameters.
(2) This parameters can only be changed in stopping state and can not be changed in running state.
(3) Parameters have been protected. If the lowest bit of P3.01 is set to 1 or 2, all the parameters can not be changed. If you
really want to change the setting, please set P3.01 to 0 in advance.
3. Jog
Suppose the current running command channel is operate panel, machine is standby, jog frequency is 5Hz:
Fig. 3-9 Jog Operation
4. Set user password
Set password PF.01 as “2345”. The bold bit indicates flashing digit.
Fig. 3-10
Input user’s password
LED Dispaly
Key Operation