V5 series inverter
40
P3.25
Decerlate time 7
0.1~6000.0
0.1
10.0
○
P3.26
Multi-frequency 1
Min frequency~max frequency
0.01Hz
5.00Hz
○
P3.27
Multi-frequency 2
Min frequency~max frequency
0.01Hz
10.00Hz
○
P3.28
Multi-frequency 3
Min frequency~max frequency
0.01Hz
20.00Hz
○
P3.29
Multi-frequency 4
Min frequency~max frequency
0.01Hz
30.00Hz
○
P3.30
Multi-frequency 5
Min frequency~max frequency
0.01Hz
40.00Hz
○
P3.31
Multi-frequency 6
Min frequency~max frequency
0.01Hz
45.00Hz
○
P3.32
Multi-frequency 7
Min frequency~max frequency
0.01Hz
50.00Hz
○
P3.33
Jump frequency 1
0.00~500.00Hz
0.01Hz
0.00Hz
×
P3.34
Range of jump frequency
1
0.00~30.00Hz
0.01Hz
0.00Hz
×
P3.35
Jump frequency 2
0.00~500.00Hz
0.01Hz
0.00Hz
×
P3.36
Range of jump frequency
2
0.00~30.00Hz
0.01Hz
0.00Hz
×
P3.37
Jump frequency 3
0.00~500.00Hz
0.01Hz
0.00Hz
×
P3.38
Range of jump frequency
3
0.00~30.00Hz
0.01Hz
0.00Hz
×
P3.39
Set running time
0~65.535K hour
0.001K
0.000K
○
P3.40
Accumulate running time
0~65.535K hour
0.001K
0.000K
*
P3.41
Display parameters
selection 1
0000~FFFF
Lowest bit: b-09~b
-
12
Ten bit: b-13~b
-
16
Hundred bit: b-17~b
-
20
Thousand bit: b-21~b
-
24
1
0000
○
P3.42
Display parameters
selection 2
0000~FFFF
Lowest bit: b-25~b
-
28
Ten bit: b-29~b-32
Hundred bit: b-33~b-36
Thousand bit: b-37~b-40
1
0000
○
P3.43
Display parameters
selection 3
0000~4040
Ten bit, lowest bit: stop displayed
parameter selection
Thousand bit, hundred bit: run dis-
played parameter selection
1
0001
○
P3.44
Display
coefficient without unit
0.1~60.0
0.1
1.0
○
P3.45
JOG/REV shift control
mode
0: Jog running
1: reverse running
1
0
×
5. Function parameters of terminal (Group P4)
Group P4: Function Parameters of Teriminal
Parameter
Name
Range
Minmum
unit
Factory
setting
Change
P4.00
Function selection of
input terminal X1
0: Control terminal is idle
1: Multi-speed control
terminal 1
2: Multi-speed control
1
1
×