background image

 

18 

Item   

XSDH-60A32-E 

XS3-26T4 

XSLH-30A32 

2

 

Output   

24 points Y0~Y27 

8 points Y0~Y7 

16 points Y0~Y17 

Max I/O points 

572 points 

1050 points 

542 points 

High speed 

processing 

function 

High speed count, external interrupt 

External 

interrupt point 

X2~X7, X10~X13, X16, X21, 

X24, X27 

X2, X5, X10, X13, X16, X21,   

HSC0, HSC2, HSC4, HSC6 

X2~X7, X10~X13 

Note: I/O points refers to the terminal numbers user can access from outside and output signal. 

 

2-2

Dimension 

2-2-1

XSDH series PLC dimension 

(Unit: mm) 

X

Y

XSDH-60A32-E

ERR

RUN

PWR

90.0

108.0

100.0

177.2
169.2

 

2-2-2

XS3 series dimension 

(Unit: mm) 

Summary of Contents for XS Series

Page 1: ...XS series PLC User manual Hardware Wuxi Xinje Electric Co Ltd Data No PS01 20211214EN 1 0 1...

Page 2: ...up backup and safety functions by yourself to avoid possible machine failure or loss caused by the failure of this product Statement of responsibility Although the contents of the manual have been car...

Page 3: ...anger When it is used incorrectly it may cause danger cause personal injury or serious injury and may cause serious property damage Confirmation upon receiving the product Attension Do not install dam...

Page 4: ...devices expansion devices batteries and other devices be sure to cut off power for operation It may cause malfunction and fault Product wiring Danger 1 Before wiring the controller be sure to disconn...

Page 5: ...ic shock 3 Please stop the program in the controller before changing it It may cause malfunction Attension 1 Do not disassemble or assemble this product without authorization It may cause damage to th...

Page 6: ...tion and model table 12 1 3 PART INTRODUCTION 14 1 3 1 XSDH series structure composition 14 1 3 2 XS3 series structure composition 15 1 3 3 XSLH series structure composition 16 2 MAIN BODY SPECIFICATI...

Page 7: ...3 5 1 3 XSLH series input specification 34 5 2 DC INPUT SIGNAL 36 5 3 HIGH SPEED COUNT INPUT 37 5 3 1 Count mode 37 5 3 2 High speed counter range 38 5 3 3 High speed counter input wiring 38 5 3 4 Inp...

Page 8: ...rature expansion XD E4PT3 P XD E6PT P XD E2TC P XD E6TC P XD E6TC P H Mixed expansion XD E3AD4PT2DA XD E2AD2PT2DA Weighing extension XD E1WT C XD E2WT C XD E4WT C XD E1WT D XD E2WT D XD E4WT D SSI enc...

Page 9: ...re measurement XL E4TC P XL E4PT3 P Pressure measurement XL E1WT D XL E2WT D XL E4WT D Conventions in the manual Due to space limitations some abbreviations may be used in the manual to replace the or...

Page 10: ...manual XS series PLC user manual motion control Introduce the usage of XS series PLC advanced motion control instructions PDF Expansion module manual XD series PLC expansion module user manual Introd...

Page 11: ...pecial functions Basic functions High speed operation The main processor of XSDH series PLC has a main frequency of 1GHz which can meet the requirements of high speed operation Rich expansion modules...

Page 12: ...n reach 200kHz and AB phase can reach 100kHz Interrupt function XSDH series PLC has 14 channel external interrupt function Online download XSDH series PLC supports online download function to truly re...

Page 13: ...s communication supports up to 32 stations 32 axis motors can be controlled synchronously and supports communication with EEPROM slave stations such as Xinje DS5C Inovance servo Panasonic EtherCAT ser...

Page 14: ...al functions Basic function High speed operation The main frequency of the main processor of the XSLH series PLC is up to 1GHz which can meet the requirements of high speed operation The minimum execu...

Page 15: ...n realize faster and more stable program data download and better real time performance It supports PLC access to the Internet and realizes remote search online monitoring uploading and downloading of...

Page 16: ...input and output expansion module analog module and temperature control module I O expansion module Input 8 32 points Output points 8 32 Output type transistor relay Power supply DC24V Analog module...

Page 17: ...rol 32 EtherCAT axes Power supply E AC220V 2 Basic unit model list XSDH model list Model Input points DC24V Output points R T AC power supply DC power supply Relay output Transistor output Relay trans...

Page 18: ...E 4AD 2DA 6PT 6TC 1WT P 4SSI H Expansion E Expansion module Analog input 4AD 4 channels analog input 8AD 8 channels analog input 12AD 12 channels analog input Analog output 2DA 2 channels analog outpu...

Page 19: ...built in PID control XD E6TC P H 6 channels K type thermocouple input built in PID control each channel is isolated from each other XD E2TC P 2 channels K type thermocouple input built in PID control...

Page 20: ...ion unit model composition and model table 1 I O expansion module The model composition of I O expansion module is as follows XG E 1 2 3 4 5 6 1 Series name XG 2 Expansion module E 3 Input points 8 16...

Page 21: ...g input current type XG E8AD V 8 channels analog input voltage type XG E4AD2DA 4 channels analog input 2 channels analog output XG E4DA 4 channels analog output Temperature measurement XG E8PT3 P 8 ch...

Page 22: ...N input X PNP input PX Output points 8 or 16 or 32 Output mode YR relay output YT transistor output Wiring terminal type A horn terminal I O expansion module model list Model Function NPN input PNP in...

Page 23: ...hardware version differences for WT module V input is voltage for 8AD module Accuracy S 16 Bit List of analog quantity and temperature expansion module models Model Description Analog input XL E4AD 12...

Page 24: ...precision 1 3 Part introduction 1 3 1 XSDH series structure composition X Y XSDH 60A32 E ERR RUN PWR 12 11 10 13 7 6 5 3 4 15 9 8 2 1 14 16 17 The names of each part are as follows Note the dial swit...

Page 25: ...ion with external terminal blocks and adaptive connecting cables Refer to section 3 2 4 for details 1 System indicator PWR power supply indicator RUN run indicator ERR error indicator 2 Input label an...

Page 26: ...ed to users The purpose of the dial switch under the cover plate location 21 is as follows DIP1 DIP2 Function OFF OFF Start the PLC normally and use it normally OFF ON The user program is not loaded a...

Page 27: ...port 4 RJ45 LAN2 support EtherCAT bus control Communication port5 CAN support CANopen bus control only for XSLH Installation Fix with M3 M4 screws Grounding FG The third grounding It shall not be gro...

Page 28: ...speed count external interrupt External interrupt point X2 X7 X10 X13 X16 X21 X24 X27 X2 X5 X10 X13 X16 X21 HSC0 HSC2 HSC4 HSC6 X2 X7 X10 X13 Note I O points refers to the terminal numbers user can a...

Page 29: ...19 130 0 48 0 133 4 2 2 3 XSLH series PLC dimension Unit mm XSLH 30A32 FG 0V 24V A B ECAT ENET CAN CAN GND COM1 15 ON OFF 70 77 8 5 1 111 5 105...

Page 30: ...M3 Y7 Y6 Y5 Y4 COM2 Y3 Y2 COM1 B 0V 24V COM6 Y24 Y25 Y26 Y27 Note refer to chapter 5 1 for details 2 3 2 XS3 series terminal arrangement 1 Main body terminals 2 External terminal block L X0 X1 X2 X3 X...

Page 31: ...connect the touch screen communicate with some instruments etc A B 3 LAN port Ethernet RJ45 port the Ethernet port is RJ45 interface with stable and convenient communication mode It can be used for up...

Page 32: ...y understand the connection between PLC and peripheral equipment expansion equipment etc as well as the typical applications of PLC communication connection and expansion ports RS485 RS485 LAN LAN XG...

Page 33: ...tent communication protocols generally through Modbus TCP protocol The specific parameters depend on the HMI connection The HMI of Xinje company can be directly connected with the basic unit for commu...

Page 34: ...3 Power supply module XS3 series medium sized PLC is equipped with a special power module the model is XG P75 E and its basic specifications are as follows Item Specification Power supply AC100 240V O...

Page 35: ...al terminal blocks can be selected for XS3 series wiring Xinje provides terminal blocks and connecting cables required by XS3 for users to choose List of terminal blocks and connecting cable models Ma...

Page 36: ...in conjunction with external terminal blocks Xinje provides JC G26 NN05 JC G26 NN10 JC G26 NN15 cables of different lengths and specifications for users to choose Please note that when connecting one...

Page 37: ...expand up to 16 modules After connecting the basic unit and the expansion module with the bus connector the PWR indicator of the expansion module is on and the expansion module can be used normally 3...

Page 38: ...xpansion module guide rail installation or direct screw installation can be selected Install with DIN46277 guide rail X Y XSDH 60A32 E ERR RUN PWR The unit and expansion module are installed on DIN462...

Page 39: ...ook on the upper side of the PLC body to the upper side of the installation guide rail according to the direction shown in the figure Fix the PLC to the mounting rail as shown in the following figure...

Page 40: ...on module does not need to install U connector 3 XSLH series installation Installation of basic unit and expansion module rail installation is optional Use DIN46277 rail to install XSLH 30A32 FG 0V 24...

Page 41: ...ower cables to prevent voltage drop 2 Even in case of power failure within 10ms the programmable controller can still continue to work When the power is cut off for a long time or the abnormal voltage...

Page 42: ...signal mode Contact input or NPN open collector transistor Circuit insulation Optoelectronic coupling insulation Input action display LED is on when input is on Note X2 X5 X10 X13 are high speed optoc...

Page 43: ...series PLC supports NPN and differential input modes The specific specifications and wiring mode are described below 1 NPN mode Item Content Input signal voltage DC24V 10 Input signal current 7mA DC2...

Page 44: ...s when input is ON Differential input wiring example Differential wiring diagram example 5 1 3 XSLH series input specification XSLH series PLC supports NPN and differential input modes The specific sp...

Page 45: ...or NC proximity switch wiring diagram 3 wire NPN type proximity switch wiring diagram 2 Differential mode Item Content Differential input 4 points X0 X1 X3 X4 Input signal 5V differential signal Input...

Page 46: ...isoperation caused by input contact vibration or input line mixed noise Due to the above reasons for input ON OFF OFF ON changes the response time lags about 10ms inside the PLC Digital filter is buil...

Page 47: ...be sure to select the encoder of differential signal DIFF X0 X1 X0 X1 X2 X3 X3 X4 X4 B A sensor Rotary encoder Count input B A When the counting frequency is higher than 25Hz please select the high s...

Page 48: ...counter input wiring For the counting pulse input terminal wiring it is slightly different according to the programmable controller type and counter model Several typical input terminal wiring methods...

Page 49: ...1MHz in differential mode 80KHz in single phase mode and 50Khz in AB phase mode When the X input terminal is not used as a high speed input port it can be used as a common input terminal The specific...

Page 50: ...00k 200k 100k 100k 100k 100k X0 U A X1 B X2 X3 U A X4 B X5 X6 U A X7 B X10 X11 U A X12 B X13 XSLH 30A32 Single phase incremental mode AB phase mode CounterID 0 1 2 3 0 1 2 3 Max frequency 1M 1M 80k 80...

Page 51: ...iring press the yellow spring switch with a small screw drive insert the wire into the corresponding socket and release the spring switch 6 2 Transistor output 1 General transistor output External Pow...

Page 52: ...ver Make sure the driver s photoelectric coupling input terminal has 8 15mA reliable current 2 Output circuit protection For inductive load of DC circuit freewheeling diode shall be added as shown in...

Page 53: ...the program in the PLC is found to be wrong and needs to be modified it is necessary to rewrite the program to the running PLC Use Ethernet cable to connect PLC and computer Upload the program in the...

Page 54: ...conductive dust falling inside the PLC Try to make the PLC operation and storage environment conform to the standards described in section 2 1 1 of this manual 2 About the battery There are no compone...

Page 55: ...wing problems 1 Communication parameters the communication parameter settings of PLC communication port and peripheral equipment may be inconsistent 2 Communication cable the connection may be incorre...

Page 56: ...N power on does not load the user program and scan the connected device again If the connection can be scanned an empty program will be downloaded at this time After the abnormal program is erased the...

Page 57: ...WUXI XINJE ELECTRIC CO LTD No 816 Jianzhu West Road Binhu District Wuxi City Jiangsu Province China 214072 Tel 400 885 0136 Fax 510 85111290 www xinje com...

Reviews: