Operation
Observe correct mains voltage!
The voltage of the power source must agree with the voltage specified
on the type plate of the power tool.
Before any work on the power tool itself, pull the mains plug.
Switch action
Switch on
:
Press the switch towards
①
direction
Switch off
:
Release the switch towards
②
direction
If continuous Operation, turn on the switch 5 and then push in The
lock button6, to stop from the locked Position , just press
the Switch 5 fully, then Release it.
NOTE
:
If the power tool is used at a low temperature, or it is used after a long idle time, this demolition
hammer should be kept running for above 5 minutes to warm up.
Shock absorption Equipment 4
The XP-G50VA is equipped with an active vibration reduction system, which cuts vibration of that of the
without Active Vibration Reduction. This may significantly reduce the exposure level over the total
working period. protect the operator form the effects of vibration.
Setting the Impact Rate
The electronic control enables stepless speed preselection in accordance with the material to be worked.
The constant electronic control keeps the preselected impact rate nearly constant between no-load and
load conditions.
Select the impact rate with the Speed Adjuster Function Knob 6 according to the material.
Changing the Chiselling Position (Vario-lock)
The chisel can be locked in 12 positions. In this manner, the optimum working position can be set for each
application.
Insert the chisel into the tool holder.
Push the Move limited ring 3 forward and turn the chisel to the required position with the Move limited
ring 3.
Release the Move limited ring 3 and turn the chisel until it latches.