6
9.
Do not use the power tool with a damaged cord. Do not touch the damaged cord and pill the
plug from the outlet when the cord is damaged while working.
Damaged cords increase the risk
of an electric shock.
Warning:
Reduce the working time to avoid risks related with too much vibration.
In this operator's manual/or machine’s labels following symbols are used:
Accordance with essential applicable safety of European directives
Double insulation
Denote risk of personal injury, loss of life
or damage to the tool
in case of nonobservance of
the instruction in this manual.
Indicate electrical shock hazard.
Immediately unplug the plug from the main electricity in the case that the cord gets damage
and during maintenance.
Wear ear and eye protection.
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Waste electrical products should not be disposed of with house hold waste, Please recycle
where facilities exist. Check with your local Authority or retailer for recycling advice.
SPECIFICATIONS
Model No
XP-R48VA
ID No.
8 8018 010
Voltage
220-240V
Frequency
50Hz
Rated power
1350W
No load speed
250-500 min
-1
Impact rate
1900-3000min
-1
Impact energy
2-14J
Capacity
Drill bit:
Φ
48mm
Core bit:
Φ
120mm
Optimum drilling diameter in concrete
Φ
22-
Φ
40mm
Weight (without cord)
7.4kg
*Note type designation on the device, differences might depend on area.