background image

Safety Instruction

Considerations

Please ensure that you have read and understood the safety precautions
described in the following text before using the product so that you can 
operate it correctly.
The safety precautions described in the following text guides you to operate 
the product and its accessories correctly and safely to avoid damage and 
loss to you,other people and the device.

The warning describes the acts that may cause harm to users. Please 
observe the following operation in order to avoid electric shock or personal 
injury.

If the product case is damaged, don’t use it continuously.

Please contact the local distributors or agents of Xintai under such 
condition.

Warning: Don’t aim the laser pointer at human or 
animal's eyes.  The laser given out by the laser 
pointer may harm the vision.

Please observe the following guide in order not to damage the product:

Don’t assemble or dismantle the product without permission.

The product is a type of super precise equipment. Don’t try to dismantle,
assemble or remodel any part of the product. Repair of the product should 
be made by technical personnel designated by Xintai Company.

Avoid damage to probe of the product

Note: don’t put the product close to strong heat source directly (such as 
electric iron). Otherwise, it may damage the probe of the product.

Product hum

When the product works, there is light sound of clicking every several
seconds. This is normal phenomenon that the lens captures images.

Warning

During the process of use, if the product is found with smoke,
spark and the burnt smell, please stop using at once.

In case of such condition, the product power supply should be
powered off first.After the smoke and peculiar smell disappears 
completely, please contact the local distributors or agents of Xintai.

Don’t remodel the adapter and the data line.

Otherwise, such remodeling may cause short circuit or fire.

www.xintest.com.cn

3

www.xintest.com.cn

4

Summary of Contents for HT H8

Page 1: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 2: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 3: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 4: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 5: ...of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and lowest temperature of the thermal images The selectable color pal...

Page 6: ...ttery level is low the top right of the screen will display Please charge in time through Micro USB interface www xintest com cn 11 www xintest com cn 12 Infrared image resolution Visible image resolution LCD resolution Field angle Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette 300000pixel ...

Page 7: ...ture Storage temperature Relative humidity Working time Built in chargeable 26650 battery Detachable Selectable 5 minutes 20 minutes not power off automatically 0 to 45 20 to 60 85 RH 3 4 hours JPG Setting command Language Unit language date time information USB Micro USB 2 0 1 www xintest com cn 13 www xintest com cn 14 Storage capacity Built in 8G Actually available 6 6G 256mm 97 2mm 128 9mm 635...

Page 8: ...corner of the screen Battery Micro USB Please open the cap in use 2 www xintest com cn 15 www xintest com cn 16 The highest temperature cursor used to indicate the highest temperature position in the screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen Maximum value minimum value of fiel...

Page 9: ...t up press key and the screen bottom will display highest lowest temperature column Press can also hide it LCD screen display After turning on the power the screen shows the thermal imaging status Note Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures Image capture Press the image capture key When the capture is successful the sc...

Page 10: ...in Use USB line to connect the USB port and then computer to read the images or save it into computers images or save it into computers Measuring temperature range conversion Press the button for 2 seconds the temperature measurement range is 20 C 550 C and the icon will be displayed on the interface Press the button for 2 seconds the temperature measurement range is 20 C 120 C and the icon will b...

Page 11: ...alette Press to return Press MENU key to exit from the menu The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide addit...

Page 12: ...with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivity will produce giant impact on surface temperature measured by the product Understanding the surface emissivity will enable you to obtain correct temperature mea...

Page 13: ... change the value After themodification is completed press SELECT ENTER to confirm then press to return The MENU button exits the menu www xintest com cn 25 www xintest com cn 26 Thermal radiation 0 90 0 98 0 94 0 96 0 90 0 92 0 96 0 92 0 96 0 96 0 98 0 90 0 95 0 90 0 94 0 94 0 80 0 90 0 89 0 91 0 93 0 96 0 83 0 98 0 98 0 75 0 80 0 96 0 80 0 95 0 97 0 94 0 90 0 70 0 94 0 81 0 78 0 78 0 82 0 90 0 8...

Page 14: ...ngs sub menu select MENU automatic shutdown press navigationThe button in the button enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 4 3 Language Settings After selecting l...

Page 15: ...turn Press MENU exit from the menu As shown in the figure after selecting cold hotspot press the button in the navigation key to enter the cold hotspot setting As shown in the figure after selecting set time press in the navigation key to enter the setting time Press key to select enable or disable the option Then press SELECT ENTER key to determine selection After the setting is completed press k...

Page 16: ...4h After enabling WIFI use the mobile device to search for WIFI The hotspot name is ThermalCamera xxxxxx xxxxxx is the last six digits of the MAC access the device through the IP address 192 168 230 1 In the mobile device you can set the color palette blending degree emissivity maximum minimum value language conversion and synchro nize to the machine The settings on the machine can also be synchro...

Page 17: ...cally Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new battery or charge it The power of the battery is used up Replace with new battery or charge it The time set for automatic power off is due Restart or change the time for automatic power off after restarting refer to 4 1 Click Image in the mobile device to enter the ima...

Page 18: ...ant specification which causes damage 3 The damage is caused due to that users use and store it improperly or dismantle and repair it without permission and other reasons 4 Damage caused by natural disasters earthquake flood and lightning stroke and external disasters 5 Exceed the warranty period 1 The product enjoys warranty service within one year from the purchase date if it is used normally an...