14
DarkStar User Guide
2: Hardware
www.xkl.com
WARNING
!
When replacing laser modules, be certain that fiber and power cables have sufficient
slack to prevent damage or disconnection.
WARNING
!
Improper cleaning of the connector that goes into the Raman port of the DRA system can
result in damage to the connector. Be sure to use the included E2000 cleaning adapter
that comes with every DRA system to properly clean the E2000 connector prior to instal-
lation.
FIGURE 2.4
Replace Laser Module
Don’t bend severely
1
2
3
Slide the system forward on its
rails far enough to access the
panel. Do not strain the
attached fiber connections
when sliding the system
forward. Fiber bends should not
be smaller than 2.5” in diameter.
Using a Phillips-head
screwdriver, unscrew the nine
or five screws securing the
panel. Each screw requires
only
a quarter turn
to loosen each
screw.
To open the panel, grip the rear
side, then pull up and flip over
towards the front of the chassis.
1
2
3