![background image](http://html1.mh-extra.com/html/xlt-ovens/1832-ae-b/1832-ae-b_installation-and-operation-manual_887779015.webp)
15
The gas supply and the electrical supply are to be provided by the customer prior to instal-
lation. The picture shows a typical utility rough-in for a triple stack oven. Preparing the utilities
this way allows for an easy third deck addition if a double stack oven is initially installed.
All installations must conform to local building and mechanical codes. It is required that
the ovens be placed under a ventilation hood. The gas supply should have a gas meter and regula-
tor large enough to handle all of the gas appliances, such as the furnace, hot water heater, and ov-
ens, in operation at the same time. Add up all of the BTU / kw / MJ ratings to determine the total
load. (See Oven Specifications page for supply requirements).
Oven Only Rough-In Specifications
1. All dimensions in inches [mm].
2. All dimensions on this page are recommended.
42.00
[1067]
48.00
[1219]
6.00
[152]
3.00
[76]
Electrical Supply
Gas Manifold
6.00 [152]
From back of oven to wall
Utilities must be easily accessible when the ovens are in the installed position. Do not install utilities
behind the ovens.
NOTE
NOTE
Summary of Contents for 1832-AE-B
Page 43: ...43 This page intentionally left blank ...
Page 88: ...This page intentionally left blank ...
Page 95: ...95 Oven Schematic 1832 2440 3240 3255 3855 Square Burner Standard ...
Page 96: ...96 Oven Schematic 1832 2440 3240 3255 3855 Square Burner World ...
Page 97: ...97 Oven Schematic 1832 2440 3240 3255 3855 Round Burner Australia ...
Page 98: ...98 Oven Schematic 3270 3870 Square Burner Standard RH Control Box ...
Page 99: ...99 3270 3870 Square Burner Standard LH Control Box Oven Schematic ...
Page 100: ...100 Oven Schematic 3270 3870 Square Burner World RH Control Box ...
Page 101: ...101 Oven Schematic 3270 3870 Square Burner World LH Control Box ...
Page 102: ...102 3270 3870 Round Burner Australia LH Control Box Oven Schematic ...
Page 103: ...103 Oven Schematic 3270 3870 Round Burner Australia RH Control Box ...
Page 104: ...104 Hood Schematic Standard ...
Page 105: ...105 Hood Schematic World ...