XD-9010-TS3-W-EN Rev A 04/2009
Installation & Operation Manual
25
5.9.6. MAINTENANCE
The most critical item to be maintained is the filter on the Flow Path Pressure Generating fan (see
Figure 6 page 7). The filter is held in place by a snap-on fan guard and can be washed several times.
Regular cleaning of the Flow Path Pressure Generating fan filter is important to maintaining air
circulation within the control box and providing combustion air. Air circulation will help extend the life
of components and avoid oven down time. Depending upon store conditions, this filter should be cleaned
weekly or as it gets clogged with dust. After several cleanings the filter will need replacement.
Remember, the cleaner the filter, the cooler the control box components will be, resulting in longer
component life.
Figure 16: Filter element removal
Contact Wolfe Electric, Inc., a factory representative, or a local service company to perform all
other maintenance and repairs.
5.10. CLEANING
NOTICE:
If the oven is to be removed from its installed location for cleaning or
servicing, the following procedure is to be implemented:
1. Shut off main manual gas valve.
2. Unplug electric cord.
3. Unplug gas line.
4. Unlock casters.
5. Disconnect restraint.
6. When servicing or cleaning is complete, move oven to original location.
7. Connect restraint.
8. Lock casters.
9. Plug in electric cord.
10. Plug in gas line.
11. Turn manual gas valve on.
12. Follow normal lighting instructions.
Type A fan covers can be pulled off
from any side. Clean or replace filter.
Type B fan covers can be pried off using
a small screwdriver inserted into a
corner slot. Clean or replace filter.