AVI HOOD ELECTRICAL REQUIREMENTS
Inputs into VFD Box
The AVI Hood system provides:
Three (3) switching outputs for HVAC dampers and dedicated units
One (1) 230 VAC, 10 Amp, variable frequency, three phase power output for the ventilation
exhaust fan.
Three (3) receptacles for ovens.
One (1) 120 VAC fire alarm signal for Standard hoods, or one (1) 24 VAC fire alarm signal for
World Hoods
Outputs from VFD Box
# of Circuits
Rating
Purpose
1
230 VAC, 1 Phase, 50 Hz, 3 Amp
VFD Controller
1
230 VAC, 1 Phase, 50 Hz, 1 Amp
Lights
1
208/240 VAC, 3 Phase, 60 Hz, 3 Amp
VFD Controller
1
120 VAC, 1 Phase, 60 Hz, 1 Amp
Lights
1
230 VAC, 1 Phase, 50 Hz, 3 Amp
VFD Controller
1
230 VAC, 1 Phase, 50 Hz, 1 Amp
Lights
Australian
Standard
World
AVI Hood Electric Utility Specifications