9.
Optional Accessories
1)
Dry Contact Transmitter
NOTE: The device must be installed by qualified electrician for whom
this instruction is intended. Please read the instructions carefully before
installation. Please follow the local electrical codes.
If you are interfacing the lift with AMX or Crestron, the
Inteo Dry Contact
Transmitter
will be needed.
a)
Please refer the wiring diagram shown below to connect the dry contact
transmitter.
(Note: The dry contact transmitter doesn’t need to connect to motor. They will
interact each other by means of radio frequency.)
b)
The UP or Down positions are achieved when the up or down inputs (
▲
or
▼
) are connected with the common input C. The intermittent position is
achieved when the three inputs (
▲
,
▼
, C) are connect together.
Transmitter without front cover
Inteo Dry Contact transmitter
LED
Programming
button