6
Installation Instructions
PLEASE ENGAGE LOCAL PROFESSIONAL INSTALLER TO PERFORM
INSTALLATION. PLEASE ALWAYS FOLLOW LOCAL BUILDING
CODES, ELECTRICAL CODES AND LOCAL LAWS.
1.
Preliminary Checking:
1)
The ceiling structure should support at least
FOUR
times the total weight of
the lift and projector. Please
reinforce
additional supporting structure if
needed.
2)
Please check the overall dimensions of the lift and ensure that there is
sufficient space above ceiling before installation.
3)
45mm length and 12mm pitch louvers are arranged at left, right, front and
back cover of the lift for ventilation.
4)
100mm (4
″
) clearances from all surrounding structures are recommended. The
minimum ceiling space required for the lift to install at ceiling is
950mmWx850mmDx650mmH
for XCU 190 and
900mmWx800mmDx450mmH for XCU 180
.
The installer must be
accessible to every sides of the lift in order to install it.
5)
Check the dimensions of the projector to be mounted within the available
space.
6)
Determine the projector installation position based on projection screen
location and projector specifications.
7)
Confirm that there is adequate space for installation, operation and
maintenance.
8)
Arrange the space for service and the access to the lift.
9)
Confirm height of ceiling with maximum travel of the lift.
10)
Physically check for any damages or loose parts at the lift.
2.
Guidelines for Installation:
1)
An access from above the lift with enough clearance space should be provided
in case of any service is required.
2)
Installer must ensure that all fasteners support have adequate strength to
securely support the lift and projector.