background image

6

 

 

Installation Instructions 

 

PLEASE ENGAGE LOCAL PROFESSIONAL INSTALLER TO PERFORM 
INSTALLATION. PLEASE ALWAYS FOLLOW LOCAL BUILDING 
CODES, ELECTRICAL CODES AND LOCAL LAWS.  

 

1.

 

Preliminary Checking: 

 

1)

 

The ceiling structure should support at least 

FOUR 

times the total weight of 

the lift and projector. Please 

reinforce

 additional supporting structure if 

needed.  

2)

 

Please check the overall dimensions of the lift and ensure that there is 
sufficient space above ceiling before installation. 

3)

 

45mm length and 12mm pitch louvers are arranged at left, right, front and 
back cover of the lift for ventilation.   

4)

 

100mm (4

) clearances from all surrounding structures are recommended. The 

minimum ceiling space required for the lift to install at ceiling is 
950mmWx850mmDx650mmH

 

for XCU 190 and 

900mmWx800mmDx450mmH for XCU 180

.

  The installer must be 

accessible to every sides of the lift in order to install it. 

5)

 

Check the dimensions of the projector to be mounted within the available 
space.   

6)

 

Determine the projector installation position based on projection screen 
location and projector specifications. 

7)

 

Confirm that there is adequate space for installation, operation and 
maintenance. 

8)

 

Arrange the space for service and the access to the lift. 

9)

 

Confirm height of ceiling with maximum travel of the lift.  

10)

 

Physically check for any damages or loose parts at the lift. 

 
 
 

2.

 

Guidelines for Installation: 

 

1)

 

An access from above the lift with enough clearance space should be provided 
in case of any service is required. 

2)

 

Installer must ensure that all fasteners support have adequate strength to 
securely support the lift and projector.  

Summary of Contents for XCU 190

Page 1: ...0 X Cube Lift Model XCU 190 XCU 180 Installation Instructions...

Page 2: ...ions 4 Dimensions 5 Installation Instructions 1 Preliminary Checking 6 2 Guidelines for Installations 6 3 Installation on Ceiling 7 4 Connecting to Power Supply 9 5 Installation of Projector 9 6 Cable...

Page 3: ...stalled at the ceiling before operating 4 Please do not allow children or mental disability person to operate the equipment 5 Do not install the lift on adjacent ceiling or light fixture 6 Entire bott...

Page 4: ...om heated surface 4 Please turn off power supply or unplug before cleaning or servicing THE X CUBE LIFT Overview The lift is powered by a tubular motor which is operated on Single phase 230 240 V AC w...

Page 5: ...nsumption 100 W 100 W Voltage 230 240V AC 50 Hz 230 240V AC 50 Hz Rated Current 0 5 A 0 5 A Max Travel Distance 1500 mm 1500 mm Projector Cage W x D x H 550 x 550 x 250 mm 450 x 510 x 200 mm Exploded...

Page 6: ...5 Dimensions A mm B mm C mm D mm E mm F mm XCU 190 700 640 525 680 570 12 XCU 180 660 600 330 640 530 12...

Page 7: ...lift to install at ceiling is 950mmWx850mmDx650mmH for XCU 190 and 900mmWx800mmDx450mmH for XCU 180 The installer must be accessible to every sides of the lift in order to install it 5 Check the dime...

Page 8: ...the lift and the projector Reinforce the structure as required before installing the lift 1 Please check that the ceiling has enough space to mount the lift 2 No mounting material is provided Please...

Page 9: ...tend more than 2 600mm If the rods need to extend more than 2 please use the cross bracing to enhance the stability 8 Use the threaded locking compound angle nuts to prevent swinging 9 Adjust the thre...

Page 10: ...he recommended cable size is 1 5mm2 16AWG The power supply has to connect to the building wires and a disconnection means must be provided in accordance with the wiring rules 5 Installing Projector 1...

Page 11: ...er 1 The ceiling cover is fixed at the underside of the lift which normally greater in size and serve as platform to receive all types of ceiling materials The lift must be lowered down in order to fi...

Page 12: ...if continuous operated for more than 4 minutes If such things happen please wait for the motor to cool down and restart it again The hand held transmitter remote control is paired with the lift in fa...

Page 13: ...To delete the limit setting of this position press the UP and DOWN button simultaneously until the lift begins to move briefly up and down 2 to 3 seconds c Adjust the lift to the require position whil...

Page 14: ...op at the position preset by the factory b To delete the limit setting of this position press the UP and DOWN button simultaneously until the lift begins to move briefly c Adjust the lift to the requi...

Page 15: ...opped in the position before setting more than 4 seconds c To delete the intermittent position that previously recorded press STOP button the lift will travel to the position that recorded d Press and...

Page 16: ...ntact Transmitter will be needed a Please refer the wiring diagram shown below to connect the dry contact transmitter Note The dry contact transmitter doesn t need to connect to motor They will intera...

Page 17: ...the three positions are correctly recorded by pressing UP DOWN and STOP buttons on hand held transmitter remote control e Press and hold the Programming button at the back of the hand held transmitter...

Page 18: ...ree positions are memorized by the Dry Contact Transmitter which automically quits its programming mode NOTE TO PROGRAMMER i Please program AMX or Crestron contact closure to trigger the lift by pulse...

Page 19: ...gins to move briefly b Press and hold PROG button on back of the wall switch until the lift begins to move briefly The setting is memorized by wall switch NOTE Please visit the following link for vide...

Page 20: ...ith dry contact transmitter where manual override of control system is required XLT wall switch front XLT wall switch back Please refer the diagram below to connect XLT wall mount switch and dry conta...

Page 21: ...20 XLT wall mount switch Dry Contact Transmitter...

Reviews: