background image

INDEX

 

USER MANUAL - OPTIMA RT9W 1K/2K/3K 

 

 

www.xmart-ups.com 

VER.171130-WP+-ENG

 

20 

 

13.

 

SUPPORT & WARRANTY 

 

 

Support: 

If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved, please 

contact authorized service center or authorized dealer. 

 

Batteries:

 Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out. This is not 

a defect or failure so that batteries wear out is not covered by this warranty. 

Battery  lifetime  will  depend  of  operative  conditions  like  working  temperature,  type  and  frequency  of  discharging  cycles.  Higher  the 

temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical applications batteries 

should be revised and replaced periodically. Long storage (longer than 6 months) without required recharging will wear out batteries. This 

situation is not covered by this limited warranty since this is not considered as a defect. Check recharging instructions on user manual. 

 

Conditions - Limited Warranty 

1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and workmanship at 

the time of XMART supplies the product. 

 

In Europe, warranty time is 2 years on electronic parts and 2 years on internal batteries from XMART invoice date. 

 

In America, standard warranty times could vary depending on country/region or can be extended by purchasing warranty options. 

Please check warranty plans and extensions with your local distributor.  

2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or workmanship, 

authorized distributor or service center will, at their option, either repair or replace the product in accordance with terms and conditions 

stipulated herein. Transportation expenses are not covered by this limited warranty. 

3.- Warranty is valid only if the original purchasing document, specifying date of purchase, serial number and name of the dealer, is 

presented  with  the  product  to  be  revised.  XMART  and  authorized  partners  reserve  the  right  to  refuse  warranty  service  if  any  of  this 

information has been removed, changed or missing in original invoice document. 

4.- If product is repaired or replaced, repaired or replaced product will be warranted for the remaining time of the original warranty or for 

90 days on repaired part from date of repair, whichever is longer. 

5.- XMART or their distribution/service partners reserve the right to charge handling fee if returned product is free of failure or it is out of 

warranty because any of the reasons described in this warranty.  

6.- If product is out of warranty a reparation proposal will be sent to the user for his approval. If proposal is not accepted, service center 

will keep product available for the user during 60 continuous days. After this period product would be disposed and user will not be able 

to rise any claim.  

7.- Rechargeable batteries, like included in this product, will definitively wear out even under normal operation. This is not a defect or 

failure so it is not covered by this warranty.  

8.- This warranty does not cover batteries wear out caused by improper or long storage (over 6 months without required recharging as 

indicated in product manual). Even performing recharging procedure this product cannot be storage longer than 18 months. Problems on 

batteries caused by this kind of long storage are not covered by this warranty. 

9.- This warranty does not cover product failures caused by installations, modifications or repair performed by non-authorized person. If 

product is open by not authorized technician warranty will be considered void. This warranty does not cover failure caused by inadequate 

installation or maintenance, misuse, accidents, fire or floods. 

10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a failure it is 

caused by an improper product installation. Input fuse or breaker reset, or replacement is not covered by this warranty.  

11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper packing of 

the product by user. 

12.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART. 

 

Limited Warranty 

- XMART does not warrant that the operation of this product will be uninterrupted or error-free during its lifetime. If product fails to work, 

the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you have paid for the product or 

the cost of repairing or replacement of any hardware components that malfunction in conditions of normal use. 

- In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including any lost profits 

or savings or special, incidental, or consequential damages. XMART is not liable for any claim made by a third party to XMART or to final 

user.  

- XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this hardware product. 

 

 

 

 

 

 

Summary of Contents for OPTIMA RT9W 1K

Page 1: ...n this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or...

Page 2: ...ONS 2 PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 10 S...

Page 3: ...its own power outlets this could damage the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the UPS based on inrush current instead of average current Inr...

Page 4: ...of this product as a part of a more complex system not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment It also could affect its per...

Page 5: ...y by these handles 1 Install black handles to the UPS 2 Make sure rack cabinet counts with required mounting guides 3 Place UPS on the guides and fix it to the cabinet using black handles VERTICAL MOU...

Page 6: ...must connect line neutral and ground to input terminal block using cables with required gauge to drive maximum rated current For 3KVA UPS in 120V wires must be minimum 12AWG for lengths shorter than...

Page 7: ...off 2 Bypass mode is adopted as soon as a problem is detected in its internal circuitries 3 Bypass mode is also activated in case an external overload is detected in UPS output It happens when equipme...

Page 8: ...y UPS inverter C AC input symbol must be turned off representing there is no valid AC input detected by UPS D Clock symbol lights and backup time is displayed on the screen BYPASS MODE A Input and out...

Page 9: ...R UPS TURN OFF Press for 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALUES UPS can show in alternative cycle all available values by push...

Page 10: ...INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also shows...

Page 11: ...5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the UPS 25 Supplied Power...

Page 12: ...configuration mode LCD displays ID of the menu and values of 2 adjustable parameters 1 MENU ID 2 Function name 3 Configurable value KEYBOARD IN CONFIGURATION MODE ON MUTE Used as key to navigate or ch...

Page 13: ...F 50 50Hz CF 60 60Hz 04 ECO ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS Check more details at operation modes section 05 ECO INPUT VOLTAGE RANGE Vac Function 02 High Limit Function 03 Low Li...

Page 14: ...n Funci n de Convertidor de Frecuencia CH Charger Cargador de Bater as ESC Escape Salir ON ON Encendido ENA Enable Habilitado DIS Disable Des habilitado HLS High Loss L mite superior del rango LLS Low...

Page 15: ...ms are generated when UPS detects an abnormal situation but UPS can continue working in ONLINE mode However it is important operator revise condition that generated alarms and take actions to solve it...

Page 16: ...ON ERROR CODE ERROR SYMBOL DC BUS start failure 01 DC BUS High 02 DC BUS Low 03 DC BUS Unbalanced 04 INVERTER start failure 11 INVERTER High voltage 12 INVERTER Low voltage 13 SHORT CIRCUIT detected a...

Page 17: ...f not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 04 Turn off and power off UPS Disconnect all equipment connected to UPS Restart UPS with no loads connected to its outp...

Page 18: ...eratures will short dramatically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged accord...

Page 19: ...3 BATTERIES 36VDC MODELS 1 5KVA 1 Remove old batteries 2 Connect 2 batteries in series 3 Install new batteries in the binder 4 Close binder BATTERY REPLACEMENT 4 BATTERIES 48VDC MODELS 2KVA 1 Remove o...

Page 20: ...ion service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is out...

Page 21: ...rotected sockets in Out C SELECT 6 Not used D OFF ENTER 7 USB RS232 ports 1 Standard UPS outlets 8 Intelligent SNMP port 2 IEC C20 outlet 16A IEC model only 9 External Battery connector optional in so...

Page 22: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 22...

Page 23: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 23...

Page 24: ...12V 9AH 6 x 12V 9AH 27 4 VDC 1 54 7 VDC 1 82 1 VDC 1 276 491 737 100 105 warning 105 110 10min to bypass 110 130 1min to bypass 100 105 warning 105 110 10min to bypass 110 130 1min to bypass 110 120 3...

Page 25: ...ows to set output frequency at constant value 50Hz or 60Hz El modo de Conversi n de Frecuencia permite fijar la salida a 50 o 60Hz Runtime for loads 80 is limited to 4min For loads between 70 and 80 r...

Page 26: ...INDEX USER MANUAL OPTIMA RT9W 1K 2K 3K www xmart ups com VER 171130 WP ENG 26 NOTAS...

Page 27: ......

Page 28: ...NW 26th St Doral FL 33172 USA sales xmart ups com EUROPE Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain sales xmart ups com Latin America Zona Ind San Vicente II C F A11 Maracay Venezuela sales xmart...

Reviews: