CF: ENABLE / DISABLE FREQUENCY CONVERTER FUNCTION:
CF can be enable/disable by setting PAR. 03:
CF = Enable
NCF = Disable
If CF is enable PAR 02 must be set to preferred frequency value: 50Hz or 60Hz
This function allows UPS to generate output at selected frequency no matter value of
input frequency
03
CF: FREQUENCY OUTPUT VALUE
- Initial frequency at Battery mode can be set:
BAT 50 = 50Hz
BAT 60 = 60Hz
- With CF mode activated, Output in ONLINE mode can be set as:
CF 50 = 50Hz
CF 60 = 60Hz
04
ECO ENABLE / DISABLE:
ENA : ENABLE
DIS : DISABLE
Factory set: DIS
Check more details at operation modes section.
05
ECO
–
INPUT VOLTAGE RANGE (Vac)
Function 02: High Limit
Function 03: Low Limit
Set values with keys:
&
06
BYPASS: ENABLE / DISABLE:
ENA : ENABLE
DIS : DISABLE
Factory set: DIS
07
BYPASS: INPUT VOLTAGE RANGE
- Valid input VOLTAGE range for bypass mode can be configured by setting high limit
and low limit:
PAR 03: sets high limit (in Vac)
PAR 02: sets low limit (in Vac)
Range HLS 220V: 230-V264V* / LLS 220V: 170V*-200V
Range HLS 120V: 120V-132V* / LLS 120V: 85V*-115V
Preconfigured values:(*)
08
BYPASS: INPUT FREQUENCY RANGE
- Valid input FREQUENCY range for bypass mode can be configured by setting high
limit and low limit:
PAR 03: sets high limit (in Hz)
PAR 02: sets low limit (in Hz)