USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 

 

 

www.xmart-ups.com 

VER.170502-GA2 (ENG)

 

 

1.

 

GENERAL SAFETY INSTRUCTIONS 

 

WARNING

: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating 

this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults. 

UPS manufacturer or distributor will never be responsible for any accident produced by lack of knowledge or negligent practices at the 

moment of install, starting up or maintain this product. UPS manufacturer or distributor is not liable for any damage that might rise from 

misusing this unit or defective installation.  

 

 

ELECTRIC SHOCK RISK

 

This product operates with dangerous voltages. It must be installed, operated and maintained ONLY by qualified technicians trained for 

this kind of products. Service personnel MUST know and understand very well all electric risks related to this product. 

If you are not qualified technician do not try to install, operate or repair this product. 

CAUTION:

 There are dangerous voltages in the UPS power outlets although the equipment is not plugged to power line. 

CAUTION:

 Inside this equipment, due to internal batteries, there are ALWAYS dangerous voltages, EVEN the UPS is OFF and unplugged. 

CAUTION:

 There are dangerous voltages in internal DC Capacitors. Wait at least 10 minutes after turning off UPS before opening it to 

access inside. 

CAUTION:

 Power off UPS and unplugged it from AC Line before opening it to access inside this unit. 

CAUTION:

  Before  starting  the  opening  procedure,  remove  all  jewelry  and  metallic  objects  such  as:  Rings,  Watches,  Bracelets,  etc., 

because they could contact conductive parts and components inside the UPS and this might cause discharges and/or short circuits. 

Make sure using tools properly isolated to avoid electrical risks. 

WARNING:

 This product has been designed to be used indoors protected from water, direct sun light, dust and extreme temperature. 

WARNING:

 Do not put any object on the UPS; do not apply any force over UPS. Do not cover UPS ventilation. 

WARNING:

 This UPS must be connected to appropriate electrical service according to selected model. Technical specs label in the UPS 

shows the UPS power ratings. DO NOT connect this UPS to any of its own power outlets, this could damage the unit permanently. 

WARNING:

 Do not connect AC motor based equipment without a careful sizing of the UPS based on inrush current instead of average 

current. Inrush current typical of motor based system could overload this UPS. 

WARNING:

 In case of emergency, power-off UPS and turn it off by <OFF> button in front panel. Then call technical service. 

 

 

 

INFORMATION FOR THE PROTECTION OF ENVIROMENT 

 UPS SERVICING

 

This  UPS  and  batteries  make  use  of  components  dangerous  for  the  environment  (electronic  cards,  electronic  components).  The 

components removed must be taken to specialized collection and disposal centers. 

 

NOTICE TO EUROPEAN UNION CUSTOMERS: DISPOSAL OF OLD APPLIANCES 

This  product  has  been  supplied  from  an  environmentally  aware  manufacturer  that  complies  with  Waste  Electrical  and 

Electronic Equipment (WEEE) Directive 2002/96/CE. The “crossed

-

out wheelie bin” symbol at left is placed on this product to 

encourage you to recycle wherever possible. Please be environmentally responsible and recycle this product through your 

recycling facility at its end of life. Do not dispose of this product as unsorted municipal waste. Follow local municipal waste 

electrical and electronic equipment (WEEE). 

 

 

Summary of Contents for OPTIMA T09 1K

Page 1: ...is manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or man...

Page 2: ...CTIONS 2 SAFETY QUALITY AND PERFORMANCE STANDARDS 3 PRODUCT DESCRIPTION 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 1...

Page 3: ...acelets etc because they could contact conductive parts and components inside the UPS and this might cause discharges and or short circuits Make sure using tools properly isolated to avoid electrical...

Page 4: ...additional measures only for 220 230 240VAC systems NOTE FOR 110 120 VAC SYSTEMS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of...

Page 5: ...printers Xerox copiers or scanners requires high peak power that can overload this UPS User must size UPS to maximum power required by load IMPORTANT Do not connect big loads based on AC motor or high...

Page 6: ...d on the rear panel of the UPS to confirm it marches with DC voltage provided by XBAT DC Voltage for standard T09 models T09 1K 36VDC T09 1 5K 36VDC T09 2K 72VDC T09 3K 72VDC 1 Place UPS module close...

Page 7: ...d off 2 Bypass mode is adopted as soon as a problem is detected in its internal circuitries 3 Bypass mode is also activated in case an external overload is detected in UPS output It happens when equip...

Page 8: ...ng there is no valid AC input detected by UPS D Clock symbol lights and backup time is displayed on the screen BYPASS MODE A Input and output indicators must show a similar value since output is been...

Page 9: ...UPS TURN OFF Press during 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALUES UPS can show in alternative cycle all available values by pus...

Page 10: ...T INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also sho...

Page 11: ...ed 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the UPS 25 Supplied Pow...

Page 12: ...n configuration mode LCD displays ID of the menu and values of 2 adjustable parameters 1 MENU ID 2 Function name 3 Configurable value KEYBOARD IN CONFIGURATION MODE ON MUTE Used as key to navigate or...

Page 13: ...0Hz 04 ECO ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS Check more details at operation modes section 05 ECO INPUT VOLTAGE RANGE Vac Function 02 High Limit Function 03 Low Limit Set values wi...

Page 14: ...IN AH This function must be adjusted only if external batteries are connected to the UPS Adjusted value must describe total AH internal external connected to UPS For example if UPS has internal bank o...

Page 15: ...Frequency Converter Function Funci n de Convertidor de Frecuencia CHA Charger current Corriente del Cargador de Bater as CH Charger Cargador de Bater as ESC Escape Salir ON ON Encendido ENA Enable Hab...

Page 16: ...ALARM ALARM SYMBOLS AUDIBLE BEEP OVERLOAD detected at UPS output 1 beep s LOW BATTERY 1 beep 2s BATTERY DISCONNECTED OR FAULTY 1 beep 2s BATTERY REPLACEMENT REQUIRED 1 beep 2s BATTERY DISCONNECTED 1 b...

Page 17: ...TIPO DE FALLA CODIGO DE FALLA SIMBOLO DC BUS start failure 01 DC BUS High 02 DC BUS Low 03 INVERTER start failure 11 INVERTER High voltage 12 INVERTER Low voltage 13 SHORT CIRCUIT detected at INVERTE...

Page 18: ...ervice EEPROM Failure Turn off and power off UPS Restart UPS If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off UPS Disconnect all equipment conne...

Page 19: ...atically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged according to this plan batteri...

Page 20: ...ution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is ou...

Page 21: ...170502 GA2 ENG 21 14 FRONT REAR PANEL 1 Standard UPS Outlets 6 Emergency Power Off connector 2 Programmable Outlets 7 USB RS232 3 AC Input 8 Intelligent port 4 Input AC Breaker 9 DC connector for ext...

Page 22: ...models Disyuntor para modelos de 3K NEMA Outlets power off Apagado de las salidas 400 of nominal current 5 cycles 120V MODEL 800J L N L G N G 220V MODEL 1250J L N L G N G 100 110 warning alarma 110 13...

Page 23: ...p time for programable outlets can be configurable in minutes Las salidas programables pueden configurarse en minutos N4 Shutdown voltage depends of load runtime Voltaje de corte de bater as depende d...

Page 24: ...NOTAS...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...NW 26th St Doral FL 33172 USA sales xmart ups com EUROPE Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain sales xmart ups com Latin America Zona Ind San Vicente II C F A11 Maracay Venezuela sales xmart...

Reviews: