2.

 

SAFETY, QUALITY AND PERFORMANCE STANDARDS 

 

SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC) 

UPS Part 1-1: General & Safety UPS in accessible areas 

IEC/EN 62040-1 

ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC) 

 

UPS, Part 2, Electromagnetic Compatibility: 

IEC/EN 62040-2

  

    Low Freq. Conducted Disturbances & Signals: 

IEC/EN 61000-2-2 

    Electrostatic discharge immunity Test: 

IEC/EN 61000-4-2 (Level 3) 

    Radiated radio Frequency immunity: 

IEC/EN 61000-4-3 (Level 3) 

    Electrical Fast Transient / burst immunity: 

IEC/EN 61000-4-4 (Level 4) 

    Surge immunity: 

IEC/EN 61000-4-5 (Level 4) 

    Conducted Immunity:  

IEC/EN 61000-4-6

 

    Power frequency magnetic field immunity:  

IEC/EN 61000-4-8

 

    Voltage Dips, Short Interruptions & Voltage Variations Immunity:  

IEC/EN 61000-4-11

 

PERFORMANCE: UPS Part 3: Methods of operation, specs and test requirement 

IEC/EN 62040-3 

IT Equipment. SAFETY. Part 1: General Requirements 

IEC/EN 60950-1 

BATTERY SAFETY 

EN 50272 

UL1778 (for UL models only) 

UL1778 compliant (by cTUV-US) 

IP PROTECTION 

IP20 (static) 

QUALITY MANAGEMENT: 

Manufactured under: 

ISO 9001 : 2008 

ENVIRONMENTAL MANAGEMENT: 

Manufactured under: 

ISO 14001 : 2015 

TRANSPORTATION: 

IEC/EN 60068-2-32 (Drop Test) 

 IEC/EN 60068-2-64 (Vibration Test) 

 IEC/EN 60068-2-27 (Shock Test) 

WARNING: Modifications made on the product or the use of this product as a part of a more complex system not expressly approved by the party 

responsible for compliance could void the user’s authority to operate the equipment. It also could affect its performance and

 the compliance of 

regulations. XMART is not responsible of modifications made after manufacturing. 
WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user 
may be required to take additional measures (only for 220/230/240VAC systems). 
NOTE FOR 110/120 VAC SYSTEMS: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in 
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to correct the interference at his own expense.   

 
 

 

3.

 

PRODUCT DESCRIPTION 

 

This is an Uninterruptible Power Supply (UPS) ONLINE DOUBLE CONVERSION with IGBT technology at rectifier and inverter stages with 

PWM  modulation.  It  generates  a  pure  SINEWAVE  output  free  of  noise  and  imperfections  for  powering  and  protecting  your  valuable 

system. This UPS is the right choice to protect hardware and data in critical workstations and server applications. 

This  product  has  been  designed  to  operate  under  hostile  electrical  conditions  but  offering  a  reliable  performance  with  outstanding 

features and characteristics.  Optima T09 is equipped with a powerful anti-surge system based on MOV technology.  This model has 

filtering circuits for EMI interferences. It is 100% compatible to operate connected to low quality AC sources like power generators. Soft-

start function allows connection to AC input source is done only when AC input values are confirmed inside operational ranges. 

Our  monitoring  software  allows  configuring  and  controlling  this  UPS  by  any  of  available  communications  ports:  USB/RS232  or  LAN 

Ethernet optional card (under SNMP protocol). 

 

OPTIMA T09 series has 4 different models for supporting all kind of applications from 1KVA to 3KVA: 

 

T09 1K: 1.000VA/900W 

T09 1.5K: 1.500VA/1.350W 

T09 2K: 2.000VA/1.800W 

T09 3K: 3.000VA/2.700W 

 

 

 

 

Summary of Contents for OPTIMA T09 1K

Page 1: ...is manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or man...

Page 2: ...CTIONS 2 SAFETY QUALITY AND PERFORMANCE STANDARDS 3 PRODUCT DESCRIPTION 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 1...

Page 3: ...acelets etc because they could contact conductive parts and components inside the UPS and this might cause discharges and or short circuits Make sure using tools properly isolated to avoid electrical...

Page 4: ...additional measures only for 220 230 240VAC systems NOTE FOR 110 120 VAC SYSTEMS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of...

Page 5: ...printers Xerox copiers or scanners requires high peak power that can overload this UPS User must size UPS to maximum power required by load IMPORTANT Do not connect big loads based on AC motor or high...

Page 6: ...d on the rear panel of the UPS to confirm it marches with DC voltage provided by XBAT DC Voltage for standard T09 models T09 1K 36VDC T09 1 5K 36VDC T09 2K 72VDC T09 3K 72VDC 1 Place UPS module close...

Page 7: ...d off 2 Bypass mode is adopted as soon as a problem is detected in its internal circuitries 3 Bypass mode is also activated in case an external overload is detected in UPS output It happens when equip...

Page 8: ...ng there is no valid AC input detected by UPS D Clock symbol lights and backup time is displayed on the screen BYPASS MODE A Input and output indicators must show a similar value since output is been...

Page 9: ...UPS TURN OFF Press during 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALUES UPS can show in alternative cycle all available values by pus...

Page 10: ...T INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also sho...

Page 11: ...ed 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the UPS 25 Supplied Pow...

Page 12: ...n configuration mode LCD displays ID of the menu and values of 2 adjustable parameters 1 MENU ID 2 Function name 3 Configurable value KEYBOARD IN CONFIGURATION MODE ON MUTE Used as key to navigate or...

Page 13: ...0Hz 04 ECO ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS Check more details at operation modes section 05 ECO INPUT VOLTAGE RANGE Vac Function 02 High Limit Function 03 Low Limit Set values wi...

Page 14: ...IN AH This function must be adjusted only if external batteries are connected to the UPS Adjusted value must describe total AH internal external connected to UPS For example if UPS has internal bank o...

Page 15: ...Frequency Converter Function Funci n de Convertidor de Frecuencia CHA Charger current Corriente del Cargador de Bater as CH Charger Cargador de Bater as ESC Escape Salir ON ON Encendido ENA Enable Hab...

Page 16: ...ALARM ALARM SYMBOLS AUDIBLE BEEP OVERLOAD detected at UPS output 1 beep s LOW BATTERY 1 beep 2s BATTERY DISCONNECTED OR FAULTY 1 beep 2s BATTERY REPLACEMENT REQUIRED 1 beep 2s BATTERY DISCONNECTED 1 b...

Page 17: ...TIPO DE FALLA CODIGO DE FALLA SIMBOLO DC BUS start failure 01 DC BUS High 02 DC BUS Low 03 INVERTER start failure 11 INVERTER High voltage 12 INVERTER Low voltage 13 SHORT CIRCUIT detected at INVERTE...

Page 18: ...ervice EEPROM Failure Turn off and power off UPS Restart UPS If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off UPS Disconnect all equipment conne...

Page 19: ...atically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged according to this plan batteri...

Page 20: ...ution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is ou...

Page 21: ...170502 GA2 ENG 21 14 FRONT REAR PANEL 1 Standard UPS Outlets 6 Emergency Power Off connector 2 Programmable Outlets 7 USB RS232 3 AC Input 8 Intelligent port 4 Input AC Breaker 9 DC connector for ext...

Page 22: ...models Disyuntor para modelos de 3K NEMA Outlets power off Apagado de las salidas 400 of nominal current 5 cycles 120V MODEL 800J L N L G N G 220V MODEL 1250J L N L G N G 100 110 warning alarma 110 13...

Page 23: ...p time for programable outlets can be configurable in minutes Las salidas programables pueden configurarse en minutos N4 Shutdown voltage depends of load runtime Voltaje de corte de bater as depende d...

Page 24: ...NOTAS...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...NW 26th St Doral FL 33172 USA sales xmart ups com EUROPE Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain sales xmart ups com Latin America Zona Ind San Vicente II C F A11 Maracay Venezuela sales xmart...

Reviews: