XM1630S Software Reference Manual
No. XM1630S-A00-104
xmodus swiss GmbH
9 / 32
3.2 Web based serial configuration
The serial configuration screen provides all the settings for the serial interface and the
serial communication modes.
SERIAL configuration screen:
3.2.1 Serial Port configuration:
Serial Port parameters
: setting of baud rate, parity, data-bits, stop-bits and flow-
control.
Flow Control
: Selects between RTS/CTS (Hardware) flow control and
XON/XOFF (Software) flow control. The high and low-water marks can also be
modified.
Input wait buffer
: specifies the conditions at which the received data is packed in
a TCP/IP frame and sent to the remote side. As default, received data is sent
after 350 bytes (buffer full) or after 240 ms (if less than 350 bytes received).
Modify:
To make the settings active press the “Modify serial port” button. The
new setting is immediately valid.
Save changes:
Permanently saves the new setting.
3.2.2 Communication modes:
TELNET:
The Telnet radio button enables the Telnet protocol for data
communications. Communication is established through the specified port, which
defaults to 8000.
RAW:
The RAW radio button enables transparent mode for data communications.
Communication is established through the specified port, which defaults to 8000.
IAC:
The IAC-Tx and IAC-Rx radio buttons enables IAC byte-stuffing in the
specified direction when in Raw communication mode.
Modify:
To make the settings active press the “Modify communication” button.
Save changes:
Permanently saves the new setting.