If the motor is already running (at any speed, including Intensive), pressing key 

F

 switches 

it to 1st speed for 5 minutes, after which it turns off.

When the Timer function is active, the user can change motor speed using keys 

C-D-E

 

without interrupting the 5-minute 

Timer

 function.

- If you wish to deactivate the function before the 5 minutes are up, press key 

F

 or 

B

.

- After 5 minutes, at the end of the countdown, the hood switches off (motor and any 

lights still on).

Summary of Contents for XO122SMUA

Page 1: ...Manual de utilización USA F E XO122SMUA XO128SMUA NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au numéro gratuit 800 966 8300 NECESITA AYUDA Póngase en contacto con nuestros expertos a través del número gratis 800 966 8300 ...

Page 2: ...the original purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have...

Page 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Page 4: ...ow you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION INSTRUCTIONS WARNING TO RED...

Page 5: ... the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any responsability for eventual damag...

Page 6: ... 6 Installation Ducting Calculation Sheet Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet ...

Page 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Page 8: ... 8 Hood Specifications Front of hood Side of hood Top of hood Mounting height and clearance PRODUCT DIMENSIONS AND CLEARANCE XO122S XO128S ...

Page 9: ...ht fixtures H right and left of the hood as indicated in Fig 3 step 5 RemovethelightfixturesHtomakeinstal lation easier as indicated in Fig 4 step 6 Make sure the thickness of the wall ca binet is within the measures indicated in Fig 4 step 8 1 Insert the hood inside the cabinet Fig 4 step 7 and make sure that the 4 springs F snap in place Fasten the hood to the wall cabinet using the screwdriver ...

Page 10: ... 10 Fig 3 ...

Page 11: ... 11 Fig 4 ...

Page 12: ... 12 Fig 5 ...

Page 13: ...rcuit and protected by a 15 or 20 amp circuit breaker or time delay fuse Wiring must be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 12 Connect the hood wiring to the house wiring in acco...

Page 14: ...er securing it using the screws that were previously removed The appliance should be installed at a minimum height of 27 up to a maximum height of 32 for optimal performance If a connection ductwork composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other applia...

Page 15: ... 15 Fig 1 Remove the aluminum panels by pulling the lever 1 out and pushing down wards 2 Model XORFRND carbon filter kit DUCTLESS RECIRCULATING OPTION ...

Page 16: ... 16 Fig 2 The filters C must be applied to the suction unit inside the hood centering them inside of it and turning them 90 until they snap into place Fig 3 Put the aluminum panels back in place ...

Page 17: ...absorb smoke and odors Vent grate not included 6 round or 3 1 4 x 10 rectangular recommended for best performance Some ductwork must be installed to exhaust the rengehood back into the kitchen either at the top or face of the cabinet or wood hood This duct work must not terminate into a dead air space or inside the cabinet or custom hood cabinet or custom hood hood duct work ceiling vent grate cab...

Page 18: ... back off The light level goes in this cycle high medium low off OFF key B Turns MOTOR AND LIGHTS on off When activated the matching LED turns on for 1 sec Tasto C 1st speed When activated the matching LED turns on Tasto D 2nd speed When activated the matching LED turns on Tasto E 3rd speed When activated the matching LED turns on Intensitive Key E With the motor running and any speed set press ke...

Page 19: ...which it turns off When the Timer function is active the user can change motor speed using keys C D E without interrupting the 5 minute Timer function If you wish to deactivate the function before the 5 minutes are up press key F or B After 5 minutes at the end of the countdown the hood switches off motor and any lights still on ...

Page 20: ...colour of the filters may change This does not mean they have to be replaced If the replacement and washing instructions are not followed the anti grease filters may present a fire hazard The active carbon filters are used to purify the air which is released back into the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter sa...

Page 21: ...ing too much pressure wich may mar the surface DO NOT allow deposit to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with may be ...

Page 22: ... 22 Replacing halogen light bulbs To replace the dichroic lamps rotate the lamp anticlockwise by means of a suction cup as shown in figure Replace the bulbs with new ones of the same type ...

Page 23: ... 23 XO122S XO128S ...

Page 24: ... 24 OPTIONS AND ACCESSORIES Model XORFRND carbon filter kit ...

Page 25: ... 25 INSTALLATION PREPARATION Check installation hardware Locate the hardware package packed with the hood and check contents Aluminum filter ...