- 19 -
• Power Supply Connection:
For connection to the power supply refer to the following
Fig.13
:
1. Remove the power supply cover by undoing the (2) screws
Fig.13A
.
2. Break through the hole on the box.
3. Secure the power supply conduit to the box.
4. Connect the wires of the hood to those of the power supply as described
Fig.13B
:
BLACK
=
L
line
WHITE
=
N
neutral
GREEN/YELLOW
=
G
ground
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit
fittings.
- Carry out the power supplly connection in accordance with the national electric code,
A