- 12 -
2. CONNECT ELECTRICAL:
• Power Supply Connection:
For connection to the power supply refer
to the follows
Fig.6
:
BLACK
=
L
line
WHITE
=
N
neutral
GREEN/YELLOW
=
G
ground
- A double-pole switch properly rated
must be installed to provide the range
hood power supply disconnection.
- Connect the electrical conduit to the
Field Wiring Compartment using listed
conduit fittings.
- Carry out the power supply connection
in accordance with the national electric
code, ANSI/NFPA 70-1999.
5. Insert the wires into the box, then
close the box cover, securing it using
the s c r e w s t h a t w e r e p r e v i o u s l y
removed.
The appliance should be installed at a
minimum height of 27" up to a maximum
height of 32" for optimal performance.
If a connection ductwork composed of
two parts is used, the upper part must
be placed outside the lower part. Do not
connect the range hood exhaust duct air
to the same duct air used to exhaust hot
air or fumes from other appliances other
than electrical.
•
In the
FILTERING
version it is neces-
sary to apply a metal air exhaust tube
M
(Fig.7)
, with a minimum length of 15",
connected to the flange of the collector.
It must be positioned vertically and fas-
tened to a specific opening made on the
top part of the cabinet.
Fig.6
Fig.7
3. CONNECT THE DUCTWORK:
Summary of Contents for XOI21SMUA
Page 10: ... 10 Fig 5 Fig 3 Fig 4 ...
Page 20: ... 20 XOI21SMUA XOI27SMUA ...
Page 21: ... 21 OPTIONS AND ACCESSORIES Model XORFRND carbon filter kit ...
Page 32: ... 32 Fig 5 Fig 3 Fig 4 ...
Page 42: ... 42 XOI21SMUA XOI27SMUA ...
Page 43: ... 43 OPTIONS ET ACCESSOIRES Kit filtre de recirculation sans tuyaux modèle XORFRND ...
Page 54: ... 54 Fig 5 Fig 3 Fig 4 ...
Page 63: ... 63 XOI21SMUA XOI27SMUA ...
Page 64: ... 64 OPCIONES Y ACCESORIOS Kit filtro de recirculación sin tubería modelo XORFRND ...
Page 66: ......
Page 67: ......