- 12 -
2. CONNECT ELECTRICAL:
• Power Supply Connection:
For connection to the power supply refer
to the follows Fig.6:
BLACK = L line
WHITE = N neutral
GREEN / YELLOW = G ground
- A double-pole switch properly rated
must be installed to provide the range
hood power supply disconnection.
- Connect the electrical conduit to the
Field Wiring Compartment using listed
conduit fittings.
- Carry out the power supply connection
in accordance with the national electric
code, ANSI/NFPA 70-1999.
5. Insert the wires into the box, then close
the box cover, securing it using the
s c r e w s t h a t w e r e p r e v i o u s l y
removed.
The appliance should be installed at a
minimum height of 27" up to a maximum
height of 32" for optimal performance.
If a connection ductwork composed of
two parts is used, the upper part must
be placed outside the lower part. Do not
connect the range hood exhaust duct air
to the same duct air used to exhaust hot
air or fumes from other appliances other
than electrical.
•
In the FILTERING version it is neces-
sary to apply a metal air exhaust tube M
(Fig.7), with a minimum length of 15",
connected to the flange of the collector.
It must be positioned vertically and fas-
tened to a specific opening made on the
top part of the cabinet.
�����������������
���
�
����
����
Fig.6
Fig.7
3. CONNECT THE DUCTWORK: