- 12 -
�����������������
���
Fig.5
Fig.4
• Power Supply Connection:
For connection to the power supply refer
to the following
Fig.4:
1. Remove the power supply cover by
undoing the (2) screws
Fig.4.
2. Break through the hole on the box
cover.
3. Secure the power supply conduit to
the cover.
4. Connect the wires of the hood to tho-
se of the power supply as described.
Fig.4:
BLACK
=
L
line
WHITE
=
N
neutral
GREEN / YELLOW
=
G
ground
- A double-pole switch properly rated
must be installed to provide the range
hood power supply disconnection.
- Connect the electrical conduit to the
Field Wiring Compartment using listed
conduit fittings.
- Carry out the power supplly connection
in accordance with the national electric
code, ANSI/NFPA 70-1999.
5. Insert the wires into the box, then
close the box cover, securing it using
the screws that were previously remo-
ved.
The appliance should be installed at a
minimum height of 27” up to a maximum
height of 32” for optimal performance.
If a connection ductwork composed of
two parts is used, the upper part must
be placed outside the lower part. Do not
connect the range hood exhaust duct air
to the same duct air used to exhaust hot
air or fumes from other appliances other
than electrical. Before proceeding with
the assembly operations, remove the an-
ti-grease filter(s)
(Fig.5)
so that the unit is
easier to handle.
3. CONNECT THE DUCTWORK:
Summary of Contents for XOM36G