Code Compliance Control
New!
Some local codes limit the maximum exhaust airflow of range hoods to 400 CFM
before a Make Up Air System is required.
The
XOP30SC - XOP36SC
models are supplied with 600 CFM capacity.
The
CCC system
allows you to limit the hood from 600CFM to 395 CFM.
To set up for 395 CFM Operation - follow the procedure below:
1. After the hood has been powered up initially, disconnect the power supply by shutting
off the circuit breaker.
2.
VERY IMPORTANT
, after turning power back on to the unit, you must press and hold
both the
and “0” buttons simultaneously within 5 seconds of re-powering the unit.
NOTE:
If you do not press the buttons within the first 5 seconds after turning power back
on to the hood - the CCC function will not engage and you must repeat from Step 1.
3. The control blinks 3 times
4. The hood is now configured at 395 CFM - the POWER BOOST function is also
disabled.
5. Affix the sticker supplied to indicate the unit has been reconfigured to a maximum
air flow of 395 CFM.
6. Once reconfigured for 395 CFM, the unit cannot be reset to 600 CFM.
make up air conversion