29
what the control lights mean
PROBLEM
Making Ice
Washing
Bin Full
Draining
Water Supply Error
Drain Error
Evap Temp Error
Evap Temp Error
Ice Full Sensor Error
Evap Temp Sensor
Air Temp Sensor Error
Evap Freezing
POSSIBLE CAUSE
Switch in “ICE” position
Switch in “WASH” position
ICE lamp blinks once per second
ICE lamp blinks every 2 seconds
Drain valve is open
Water level not detected
(for 2 minutes)
Water level lower limit is
undetected after 2 minutes
while drain is open
Evaporator temp is 32 or higher
after 30 minutes with Ice Making ON
Evaporator temp is 32 or higher
after 10 minutes with Ice Making ON
ICE FULL temperature sensor
disconnected of shorted
Evaporator temperature sensor
disconnected of shorted
Air temperature sensor
(front of condensor)
disconnected of shorted
Evaporator outlet temperature drops
below setting for 2 minutes while
ice maker is running
ACTION
Switch in “WASH” position
ICE lamp blinks once per second
Will turn off when sensor detects release
temperature
Water pressure and level check
Start operation after action
Check if draining properly
Replace water level sensor
Call for service
Call for service
Call for service
Sensor disconnected of shorted
Call for service
Sensor disconnected of shorted
Call for service
Sensor disconnected of shorted
Call for service
Occurs when ambient temperature is low.
Increase room temperature above 50 F.
Questions - Need Help...
You can always contact customer service at 973-403-8900
or visit www.xoappliance.com
ICE NO WATER DRAIN
O
B
B
B
B
B
B
O
B
B
B
B
O
O
B
B
B
B
O
O= ON B = BLINKING