3
Alignment instructions
1. Test equipment
PM5518 (video signal generator)
VG-849 (VGA signal generator)
CA210 (white balancer)
2 Alignment flow-chart
The alignment flow-chart is shown as fig-1
Fig-1 adjustment flow-chart
3 Unit adjustments
Connect all the boards according to wiring diagram, connect with power and observe the display.
Method for entering factory menu: press “INPUT”, “2”, “5”, ”8” and “0” in turn to enter factory menu;
press “CH+” and “CH-” to select adjustment items and press “VOL+” and “VOL-” to adjust value
items, press “MENU” continuously to exit.
3.1 Initialization
Enter factory menu, select “OPTION” and “HOTEL OPTION” sub-menu, adjustment of items to see
table1.
Table1 sub-menu adjustment
Items Preset
Introduce
HOTEL
0
1: HOTEL OPTION of factory menu is optional
0: HOTEL OPTION of factory menu is not optional
LOGO
1
1: display LOGO in no signal or turn on
0: no LOGO display
ADC PRESCALE
00A
Adjust according different power consumption
SIF PRESCALE
000
Adjust according different power consumption
Check DDC, HDCP KEY, FLASH and POWER control IC
Factory initialization setup
IF channel voltage of TV and AGC voltage adjustment
White balance adjustment
Combined test for general assembly
Performance check
Preset ex-factory
Summary of Contents for LC-26HU36S
Page 1: ...LCD TELEVISION LC 26 37 HU36S ...
Page 12: ...10 ...
Page 14: ...12 ...
Page 15: ...IF adjust Wiring diagram 13 ...
Page 22: ...page 1 of 4 ...
Page 23: ...page 2 of 4 ...
Page 24: ...page 3of 4 ...
Page 25: ...page 4 of 4 ...
Page 26: ...interface connector ...
Page 27: ...KEY board ...
Page 28: ...IR receiver board ...
Page 29: ...TV board ...
Page 30: ...26 power 1 ...
Page 31: ...26 power 2 ...
Page 32: ...32 POWER ...
Page 33: ...37 power ...
Page 34: ...26 backlight ...
Page 35: ...26 T CON ...
Page 37: ...9226HU3610 Ver 1 0 ...