become a potential safety trouble.
1.22 In addition to plasma screen, the glass is a part of high value. It has such functions as
anti-radiation, adjustment of color temperature etc. Please handle it carefully.
Alignment instructions
1. Test equipment
VG-848 (Signal generator)
CA100 (White balancer)
2. The alignment flow chart (see below figure)
Production of CPU board and analog board on the line.
Connect to central signal source; check if various
TV functions (station skipping, modulate quantity
control etc), check if the output of earphone and
speaker are normal.
Combined test for general assembly
Input AV/S signal and HDTV signal; check various
functions under AV/S terminal
Input VGA signal and check if display is normal in
the state of PC and various functions (analog
quantity control, line/field center etc.)
Check DDC, HDCP KEY and FLASH
Check CPU board and analog board
Input HDMI signal and check if display is normal in
the state of HDMI and various functions (sound
and analog quantity control).
Preset ex-factory