Safety Instructions

!

WARNING!

Please read these instructions carefully, which includes 

important information about the installation, usage and 

maintenance of this product..

The  following  symbols  are  used  to  identify  important  safety  information  on  the 
product and in this manual:

!

DANGER!
Safety hazard.
Risk of severe
injury or death

DANGER!
Hazardous
Voltage. Risk of
lethal or severe
electric shock.

WARNING!
Fire hazard

WARNING!
LED light
emission.  Risk 
of eye injury.

WARNING!
Refer to user

=

to the earth excellently. And the power connection must be operated by the 
professional technician.

=

Make sure that the working voltage will not higher or lower than the rated 
value.

=

Make sure that the cable didn't be damage or lacerated by sharp.

=

The light must be power off when it's standing idle or before clearing.

=

The cable must with plug, and you must pull out the cable by handle the plug.

=

Please be careful when installing the lighting. Never touch the bared cable, or 
it will cause the deadly electric shock.

=

Please use the suitable and safe cable to connect the light.

=

Please never remodel the light randomly, we will not take the guarantee for the 
faulty and damage which caused by dismantle

repair or remodel of the 

nonprofessional person.

=

Maximum ambient temperature 40°C. Do not operate fixture at temperatures 
higher than this.

=

Never connect the device to a dimmer pack.

=

Do not daisy chain power to more than 8 units @ 120V and 12 units @ 230V.

This light belongs to grade I protection device, therefore the light must connect 

Summary of Contents for B150

Page 1: ...1 4 in 1 USER MANUAL LED BAR...

Page 2: ...ginal factory box and packing AC POWER This fixture has an auto switching switch mode power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on...

Page 3: ...ed value Make sure that the cable didn t be damage or lacerated by sharp The light must be power off when it s standing idle or before clearing The cable must with plug and you must pull out the cable...

Page 4: ...ss Protection IP65 indoor option l Product Size 990X120X145mm l Package Size 1070X160X170 mm l N W 5 7Kg Features l RGBW color mixing with or without DMX controller l special effect minimum 16psc one...

Page 5: ...5 Product Overview MAINS IN MAINS IN DMX OUT MAINS OUT LED SIGNAL LED SIGNAL MAINS OUT DMX IN DMX IN DMX OUT Dimensions INDOOR OUTDOOR 990 145 100 120...

Page 6: ...hanging it and make sure the weight of the light is within limits of the hanger l Please make sure without any flammable objects within 0 5m when installing the light l The installation should be oper...

Page 7: ...Then proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifi...

Page 8: ...function Navigates downwards through the menu list and decreases the numeric value when in a function 4 OPERATING INSTRUCTIONS Control Panel Functions MAIN FUNCTION SUB FUNCTION SELECTION 001 512 000...

Page 9: ...of the fastest dimming curves 4 for the most slowly dimming curve Version number Enables or Disables password lockout amount set of combined lights number set of combined lights Operating instruction...

Page 10: ...isplayed Press ENTER button select DMX channel by pressing UP DOWN Press MODE to exit DMX512 Channel Values 4 channels Channel 1 2 3 4 Channel 1 2 3 4 5 6 Value 000 255 000 255 000 255 000 255 Value 0...

Page 11: ...D 10 11 LED 11 12 LED 12 13 LED 13 14 LED 14 15 LED 15 Value 000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 Description...

Page 12: ...LED 14 15 LED 15 16 strobe 17 FADE Value 000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 000 255 000 255 Description No...

Page 13: ...control Strobe 00 20Hz 1 ON 2 ON 3 ON 1 ON 2 ON 3 ON 1 ON 2 ON 1 ON 3 ON 2 ON 3 ON 1 ON 2 ON 3 ON 1 OFF 2 OFF 3 OFF Convert to 11CH 2 No Function AUTO AT01 50 Auto speed Dimmer speed 11 channels 13 M...

Page 14: ...ON Channel 8 provides individual control of the three LED modules in each fixture 245 255 switch to the 11CH 2 mode AUTO PROGRAMS Chanel 9 selects the preset Auto programs 1 50 When activating the Aut...

Page 15: ...000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 000 005 006 255 000 255 000 255 000 255 Description No Function R G B R...

Page 16: ...LUE 0 100 WHITE 0 100 60 channels 16 Master Slave Control Mode 1 Setting master machine Access control panel function by pressing MODE until is displayed Press ENTER select by pressing UP DOWN buttons...

Page 17: ...il COMP is displayed Press ENTER select C ID by pressing UP DOWN buttons Press ENTER Amount set of combined lights by pressing UP DOWN between 01 and 16 Press MODE to exit Att the number of the light...

Page 18: ...3 224 239 240 255 000 005 006 255 000 005 006 255 000 009 010 255 000 255 000 244 245 255 000 005 006 255 000 255 000 255 Description No Function R G B R G G B R B R G B W R W G W B W R G W G B W R B...

Page 19: ...in a short circuit In this event only the single LED which has failed will no longer function This does not mean that all of the LEDs have failed but the circuit is wired in series Note In the event o...

Page 20: ...rol Panel settings for correct addressing Check DMX cables Check polarity switch settings on the controller Check cable connections Call service technician Note In the event of Display PCB failure a r...