PM0622.10 – Blue Steel CXT3000/CXT4000 CompletePBX Getting Started Guide (electronic version) 

Page 

4

 of 

7

 

If you also want to define the nic1 interface, then:  
 

nmcli con mod nic1 ipv4.method manual \ 
ipv4.address 1.2.3.5/24 ipv4.gateway 1.2.3.1 
 

Define the DNS server in the /etc/resolv.conf file. For example: 

nameserver 5.6.7.8

 

Run 

systemctl restart network

 in order to apply the changes 

Note

: Correct network parameters settings are extremely important for normal 

CompletePBX functionality. Always make sure that the 'localhost' is defined in the /etc/hosts 
file:  
127.0.0.1 localhost.localdomain localhost 

Step 5: Configure the Blue Steel CXT3000/CXT4000 

If the unit is equipped with FXS ports they are configured as CompletePBX extensions starting 
from number 3001. 
In order to configure the device follow these steps: 
a)

 

From a computer’s Internet browser enter the Blue Steel CXT3000/CXT4000 IP address (for 
example http://192.168.0.64). 

b)

 

You will be prompted to define a password for “administrator”. Once you define a password 
you will be able to connect to the web interface as user 

admin

 with password that you 

defined.

 

Now you can modify your CXE2000/CXE3000 CompletePBX configuration. See the 

CompletePBX Reference Guide

 

 

Step 6: Protect CompletePBX Against Unauthorized Access 

Once you have 

fully

 

configured

 CompletePBX we highly recommend that you use the following 

procedures and applications supported in CompletePBX to protect it against unauthorized access: 

Change the Linux Password  

The password for the Linux root user can be changed by using the Linux 

passwd

 command. 

IP Protection 

CompletePBX must be installed on a protected LAN and must not be directly connected to the 
public Internet.  The LAN must be protected by a Firewall/NAT router. 

Intrusion Detection (fail2ban) and Firewall 

In order to maximize protection from external threats, the 

fail2ban

 process is activated, in 

addition to the internal firewall.  Use the Admin|Security|Firewall and Admin|Security|Intrusion 
Detection dialogs to modify the internal firewall and intrusion detection settings. 

Summary of Contents for Blue Steel CXTS4000

Page 1: ...e unit Note Not properly grounding this device will void your warranty 2 Use a star washer to securely connect a grounding tab to the grounding screw on the rear panel 3 Using 12 16 gauge wire connect the grounding tab to a reliable ground 4 All Xorcom hardware should be connected to a common grounding point Figure 1 Grounding Screw on Blue Steel Rear Panel Step 2 Powering Up the Unit 1 Connect th...

Page 2: ...able To check the received IP address by using the LCD panel Press the Menu button and then navigate as follows Status SystemInfo IP address You will see the IP address notification Scroll down by using the down arrow navigation button to review the received IP addresses for the nic0 and nic1 interfaces If an interface failed to receive an IP address from the DHCP server the display will read 0 0 ...

Page 3: ...is located below the backspace above the right hand enter key a How to obtain IP address es received from DHCP server To see the IP addresses of the nic0 and nic1 interfaces use the command ip addr show As a result you ll get a block of data like this 2 nic1 NO CARRIER BROADCAST MULTICAST UP mtu 1500 qdisc pfifo_fa link ether 00 0a cd 25 58 04 brd ff ff ff ff ff ff 3 nic0 BROADCAST MULTICAST UP LO...

Page 4: ... IP address for example http 192 168 0 64 b You will be prompted to define a password for administrator Once you define a password you will be able to connect to the web interface as user admin with password that you defined Now you can modify your CXE2000 CXE3000 CompletePBX configuration See the CompletePBX Reference Guide Step 6 Protect CompletePBX Against Unauthorized Access Once you have full...

Page 5: ...el Indication PHONE This yellow LED indicates that the Blue Steel CXT3000 CXT4000 is supplying the necessary voltage for analog or ISDN telephone sets SYNC This green LED is the synchronization It blinks once the Blue Steel CXT3000 CXT4000 is synchronized with the telephony modules ACTIVE This red LED lights up when at least one PSTN Analog phone is active ON This green LED lights up when the Blue...

Page 6: ...w blink indicates that ISDN NT layer 2 is active For more information about the unit status and port status LED indicators refer to the Astribank manual on the Xorcom Web site http www xorcom com Additional Functionality Supported by the LCD Touch Panel Internal Flash Drive for Restore Functionality In addition to the standard external Rapid Recovery disk on key all CXE series CompletePBX models f...

Page 7: ...of 7 TwinStar Status DRBD role DRBD connection status RPS Status status of power supplies in dedicated Redundant Power Supply unit which provides redundant power to Astribanks connected to the CXEn000 server Maintenance Asterisk restart DAHDI restart Server reboot Server power off Settings DHCP enable disable DHCP on particular Ethernet interface Manual Net manual IP configuration ...

Reviews: