Unit Status LED (Light Emitting Diode) Indicators 

The Blue Steel CXT3000/CXT4000 is equipped with varying LED indicators on the front panel.  

Digital Blue Steel CXT3000/CXT4000 Models  

These are models that have at least one digital PSTN port – ISDN BRI or PRI. They have a 
vertical array of four status indicators on the left side of the front panel (

Fig 2

).  

 

 

Fig. 2 – BRI/PRI Panel (allows up to additional 24 FXS ports) 

LED Label  Indication 

PHONE 

This yellow LED indicates that the Blue Steel CXT3000/CXT4000 is supplying the 
necessary voltage for analog or ISDN telephone sets. 

SYNC 

This green LED is the synchronization. It blinks once the Blue Steel 
CXT3000/CXT4000 is synchronized with the telephony modules. 

ACTIVE 

This red LED lights up when at least one PSTN / Analog phone is active. 

ON 

This green LED lights up when the Blue Steel CXT3000/CXT4000 is powered. 

 

Analog (FXS and/or FXO) Blue Steel CXT3000/CXT4000  

These models do not have digital modules and therefore have a different set of indicators, as 
described in 

Fig 3

 

Fig 3. All-Analog Panel 

The functionality of the LED indicators is the same, with two exceptions: 

1.

 

All the indicators are Red. 

2.

 

The Phone indicator is replaced with H/W LED, indicating hardware failure (when on). 

Summary of Contents for Blue Steel CXTS4000

Page 1: ...e unit Note Not properly grounding this device will void your warranty 2 Use a star washer to securely connect a grounding tab to the grounding screw on the rear panel 3 Using 12 16 gauge wire connect the grounding tab to a reliable ground 4 All Xorcom hardware should be connected to a common grounding point Figure 1 Grounding Screw on Blue Steel Rear Panel Step 2 Powering Up the Unit 1 Connect th...

Page 2: ...able To check the received IP address by using the LCD panel Press the Menu button and then navigate as follows Status SystemInfo IP address You will see the IP address notification Scroll down by using the down arrow navigation button to review the received IP addresses for the nic0 and nic1 interfaces If an interface failed to receive an IP address from the DHCP server the display will read 0 0 ...

Page 3: ...is located below the backspace above the right hand enter key a How to obtain IP address es received from DHCP server To see the IP addresses of the nic0 and nic1 interfaces use the command ip addr show As a result you ll get a block of data like this 2 nic1 NO CARRIER BROADCAST MULTICAST UP mtu 1500 qdisc pfifo_fa link ether 00 0a cd 25 58 04 brd ff ff ff ff ff ff 3 nic0 BROADCAST MULTICAST UP LO...

Page 4: ... IP address for example http 192 168 0 64 b You will be prompted to define a password for administrator Once you define a password you will be able to connect to the web interface as user admin with password that you defined Now you can modify your CXE2000 CXE3000 CompletePBX configuration See the CompletePBX Reference Guide Step 6 Protect CompletePBX Against Unauthorized Access Once you have full...

Page 5: ...el Indication PHONE This yellow LED indicates that the Blue Steel CXT3000 CXT4000 is supplying the necessary voltage for analog or ISDN telephone sets SYNC This green LED is the synchronization It blinks once the Blue Steel CXT3000 CXT4000 is synchronized with the telephony modules ACTIVE This red LED lights up when at least one PSTN Analog phone is active ON This green LED lights up when the Blue...

Page 6: ...w blink indicates that ISDN NT layer 2 is active For more information about the unit status and port status LED indicators refer to the Astribank manual on the Xorcom Web site http www xorcom com Additional Functionality Supported by the LCD Touch Panel Internal Flash Drive for Restore Functionality In addition to the standard external Rapid Recovery disk on key all CXE series CompletePBX models f...

Page 7: ...of 7 TwinStar Status DRBD role DRBD connection status RPS Status status of power supplies in dedicated Redundant Power Supply unit which provides redundant power to Astribanks connected to the CXEn000 server Maintenance Asterisk restart DAHDI restart Server reboot Server power off Settings DHCP enable disable DHCP on particular Ethernet interface Manual Net manual IP configuration ...