background image

6

LED Indicator

Aquarium Experts

LEDColor

Description

Action

Status

Solid

Poweron

N.A.

Circulating

Refilling/Pumping

N.A.

Blue

LED

Flashingwith
audiblealerts

Pumpconnection
failure

Checktheconnection
ofthepumpandthe
controller.

Alternating

&

Blue

LED

Orange

*

Flashingwith
audiblealerts

QSTalarm:
1.Bubble
interference
2.Emptyreservoir

1.Cleanthesensoror
moveittoanareaaway
frommicrobubbles.
2.Refillthereservoir.

Flashing

72-hournon-filling
reminder

1.Cleanthesensor.
2.Checkifthepump
functionsproperly.

*Pleasefollowtheinstructionabovetofixissuesandthenunplugthe
powerandplugitbackin.
**Forverysmallaquariums,thetopsensormaybetriggeredaftereachtopoff.
Thisisnormalandnoactionisrequired.

LED

Orange

Touch Button

TouchButton:SwitchofftheQSTalarm.

*Note:TouchingthebuttonwillnotcleartheQST
memory.Pleaseunplugthepowerandplugit
backintocleartheQSTmemory.

Flashingquickly
forashorttime

**

Thefail-safesensor
sensesthewater
levelchanges.

1.Cleanthesensor
2.checktheset-upof
siphonbreakandtubes.

Summary of Contents for SATO-200P

Page 1: ...Aquarium Experts Model SATO 200P Manual Sumpless ATO...

Page 2: ...aquarium surface and process the water through its chambers where activated carbon can be used to clean polish water Other ltration media can also be used based on your preference and goals These inst...

Page 3: ...nting thickness 1 2 inch 12 7 mm ATO DC Pump 1 Re ll over ow box 2 Head 8 2 feet 250 cm 1 Universal Power Supply 110 V 240 V 2 Male connector Duetto ATO Controller Female connector Flexi DC Pump Power...

Page 4: ...Flexi Over ow Box 8 Water Inlet 9 Water Outlet 8 9 Flexi Reversible DC Pump Notice 1 Please read the manual before installation Keep the power adapter dry and avoid any contact with water to prevent m...

Page 5: ...ut the lter plates on the brackets in the over ow box short side outwards and the 1 der Stick Ultra Media between the plates Close the over ow box then x the power cable of the pump with the cable cla...

Page 6: ...power adapter with the controller and the female connector of it with the Flexi DC pump Then connect power 2 3 Reservoir ATO DC Pump Optical Level Sensor Flexi Reversible DC Pump Tank Power 3 4 Siphon...

Page 7: ...shing 72 hour non lling reminder 1 Clean the sensor 2 Check if the pump functions properly Please follow the instruction above to x issues and then unplug the power and plug it back in For very small...

Page 8: ...ed from an authorized distributor or an authorized reseller This limited warranty is not transferable 2 All warranty repairs or replacement are performed by the authorized distributor or authorized re...

Reviews: