4.3. Specifications
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 ºC.
Notes:
1. Rating is percent of full scale. Rating is for operation between 10% of
minimum voltage or current rating to 100% of voltage rating and the current
rating at that voltage.
2. Minimum voltage is guaranteed at greater than 1% of the rated output voltage.
3. Minimum current is guaranteed at greater than 1% of the rated output current.
4. Measured with 20 MHz bandwidth.
5. Line frequency ripple measured with 20 MHz bandwidth (see application note
AN024 for measurement details, these measurements taken at full rated output
voltage and full power. ¬¬
6. Time for output voltage to recover within 1% of its rated output for a load
change from 70 to 100% of its rated output current at full voltage.
7. Voltage set point from 10% to 90% of rated output with rated resistive load.
When outputting current at or near the set maximum current value, voltage
rise time will be longer due to the limited current available to charge the
output capacitance.
8. Add this to the output response time to obtain the total programming time
9. Time to provide data back to the controller using LAN interface (does not
include A/D conversion time)
10. 1500 watt output is only available with an AC input of 110VAC or greater, with
lower AC line output will be limited to 1100W.
PLS15003070 PLS15005040 PLS150010020 PLS150020010 PLS15004005
DC Output Ratings
(2,3,10,11)
Voltage
30 V
50 V
100 V
200 V
400 V
Current
70 A
40 A
20 A
10 A
5 A
Power
1500 W
1500 W
1500 W
1500 W
1500 W
Output Ripple & Noise
CV p-p
(3)
45 mV
75 mV
100 mV
200 mV
300 mV
CV rms
(4)
10 mV
20 mV
40 mV
80 mV
100 mV
Load Regulation
(change from 10%-90% load)
Voltage
0.05%
0.05%
0.05%
0.05%
0.05%
Current
0.05%
0.05%
0.05%
0.05%
0.05%
Line Regulation
(change from 100-132 VAC input
or 180-260 VAC input)
(1)
Voltage
0.05%
0.05%
0.05%
0.05%
0.05%
Current
0.05%
0.05%
0.05%
0.05%
0.05%
Programming Accurancy
(1)
Voltage 0.1%+
0.1%
0.15%
0.1%
0.1%
0.1%
Current 0.1%+
0.2%
0.15%
0.15%
0.15%
0.15%
Measurement Accuracy
(1)
Voltage 0.1%+
0.1%
0.15%
0.1%
0.1%
0.1%
Current 0.1%+
0.2%
0.15%
0.15%
0.15%
0.15%
Transient Recovery Time
(6)
Time
≤
1.5 ms
≤
1.5 ms
≤
1.5 ms
≤
1.5 ms
≤
1.5 ms
Supplemental Characteristics
(supplemental characteristics are not warranted but are descriptions of typical performance determind
either by design or type testing)
Output Response Time
(settle to within ±1% of the
rated output,
with resistive load)
(7)
Up, Full Load
15 ms
30 ms
25 ms
30 ms
35 ms
Down, Full Load
25 ms
25 ms
25 ms
45 ms
40 ms
Down, No Load
<2.5 s
3 s
4 s
10 s
10 s
Command Response Time
(8)
50 ms
50 ms
50 ms
50 ms
50 ms
50 ms
Data Readback Transfer Time
(9)
5 ms
5 ms
5 ms
5 ms
5 ms
5 ms
Remote Sense Compensation
Volts/Load Lead
1 V
1 V
2 V
4 V
4 V
Over-voltage Protection
Range
0.5-33 V
0.5-55 V
0.5-110 V
0.5-220 V
0.5-440 V
Accuracy
0.3 V
0.5 V
1 V
2 V
4 V
Output Ripple & Noise
(4)
CC rms
20 mA
10 mA
10 mA
5 mA
5 mA
Programming Resolution
Measurement Resolution
(1)
Voltage 0.05%+
0.1%
0.1%
0.1%
0.1%
0.1%
Current 0.05%+
0.1%
0.1%
0.1%
0.1%
0.1%
Front Panel Display Accuracy
(1)
Voltage 0.1%+
0.1%
0.15%
0.15%
0.1%
0.1%
Current 0.1%+
0.2%
0.15%
0.1%
0.15%
0.15%