[5]

What the installer will need.

If metal switch boxes are used, earthing regulations must be followed.

Suitably rated 2-core cable –CDC100P

Suitably rated 3-core cable – CDC100T / CDC100HT

3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers.

A wall or ceiling on/off switch – CDC100T / CDC100HT. It is recommended to use a switch with an indicator light.

To  prevent  a  possible  hazardous  situation  from  water  ingress,  an  appropriate  condensation  trap  must  be 
fitted as close as possible to the fan in all situations where any section of the duct work is positioned higher 
than the fan itself.

If wall mounting the fan, you will also need:

SLWK10 Wall Kit, or alternatively, an appropriate Wall Grille and ‚100mm ducting.

A Masonry drill, hammer & chisel (or core drill equipment if available).

Mortar to make good the hole around the ducting.

If ceiling mounting the fan,

You will need the use of appropriate ancillaries for termination. These items are available from Xpelair:

1.

WT10 – Termination ducting kit.

2.

FD100 – Flexible Ducting.

3.

XCT100 – Condensation Trap.

Where to locate the fan.

Locate it as high as possible.

At least 110mm from the edges of the mounting surface to the centre of the hole.

As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room 
(e.g. opposite the internal doorway).

Near the source of steam or odours.

Not where ambient temperatures are likely to exceed 50°C.

If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill.

If  installing  in  a  room  containing  a  fuel  burning  device  which  has  a  non-balanced  flue,  it  is  the  installer's 
responsibility  to  ensure  that  there  is  enough  replacement  air  to prevent  fumes being  drawn down  the  flue 
when the fan is operating up to maximum extract. Refer to Building Regulations for specific requirements.

Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with 
energy  other  than  electric.  Requirements  of  all  authorities  concerned  must  be  observed  for  exhaust  air 
discharge and intake flow rates.

When  intended  for  use  in  possible  chemical  corrosive  atmospheres,  consult  out  Technical  Service 
Department. (For overseas markets contact your local Xpelair distributor).

Installing the isolating switch and cables.

1.

Check that the electrical rating shown inside the backplate matches your mains supply.

2.

Check there are no buried pipes or cables e.g. electricity, gas, water behind the switch location (in the wall 
or above the ceiling). If in doubt, seek professional advice.

3.

Isolate the mains supply.

4.

THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION.

5.

Lay in the cable from the isolating switch to the fan location via the on/off switch (if required).

6.

Lay in the cable from the isolating switch to the point of connection to the mains supply.

Warning: Do not make any connections to the electrical supply at this stage.

7.

Install the isolating switch and on/off switch (if required).

8.

Make all connections within the isolating switch and the on/off switch (if required).

Note:  on/off  switch  must  be  situated  so  that  it  cannot  be  touched  by persons  making  use  of  the  bath  or 
shower

.

WARNING: DO NOT MAKE ANY CONNECTIONS TO THE ELECTRICAL SUPPLY AT THIS STAGE. If in doubt, 
seek professional advice.

For Australia Only - CDC100P
Connection to the supply can be made by a flexible 2-core cable complete with 3 pin plug for insertion into an approved 10A 
GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.

For Australia Only - CDC100T / CDC100HT
These  models  are  permanently  connected  to  the  supply  and  operation  is  controlled  by  a  remote  switch.  They  should  be 
directly  wired  to  the  supply  through  an  approved  10A wall  mounted  surface  switch  with  at  least  3mm  clearance  between 
contacts.