background image

English

Wiring and setting up

D2

DX100BHTR / DX100BHTS

DX100BHPTR / DX100BHPTS

SEE DETAIL F

SEE DETAIL G

CUSTOMER 

CONNECTION 

TERMINAL

SEE DETAIL D

SEE DETAIL E

CUSTOMER 

CONNECTION 

TERMINAL

DETAIL F

SCALE 2.000

SET JUMPER TO REQUIRED 

POSITION FOR SPEED SETTING

HIGH 

SPEED

LOW 

SPEED

DETAIL D

SCALE 2.000

OVER-RUN 

TIMER

HUMIDISTAT

DETAIL E

SCALE 2.000

SET JUMPER TO REQUIRED 

POSITION FOR SPEED SETTING

HIGH 

SPEED

LOW 

SPEED

DETAIL G

SCALE 2.000

OVER-RUN 

TIMER

HUMIDISTAT

LEVEL LINE

LEVEL LINE

Summary of Contents for DX100B

Page 1: ...017AW DX100BTR 92998AW DX100BTS 93018AW DX100BHTR 92999AW DX100BHTS 93019AW DX100BHPTR 93000AW DX100BHPTS 93020AW DX100BPR 93001AW DX100BPS 93002AW Xpelair Simply Silent DX100B Installation and Mainte...

Page 2: ...e electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Installation and Maintenance Instructions English Standard Timer Hu...

Page 3: ...by the integral humidity sensor by using an external on off switch not supplied or by using the integral pull cord switch In automatic mode The built in timer automatically operates the fan for the pr...

Page 4: ...n timer setting Fan switches on at lower level of condensation anti clockwise MORE SENTITIVE RH 50 Fan runs on for a shorter time when the external switch is turned off Fan does not switch on until hi...

Page 5: ...USTOMER CONNECTION TERMINAL DETAIL C SCALE 2 000 OVER RUN TIMER DETAIL B SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED SEE DETAIL A CUSTOMER CONNECTION TERMINAL SE...

Page 6: ...SEE DETAIL E CUSTOMER CONNECTION TERMINAL DETAIL F SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED DETAIL D SCALE 2 000 OVER RUN TIMER HUMIDISTAT DETAIL E SCALE 2 0...

Page 7: ...trical supply at this stage 6 Install the isolating switch and on off switch if required 7 Make all connections within the isolating switch and the on off switch if required Wet Rooms On Off switch mu...

Page 8: ...increase and anti clockwise to decrease see Figure D1 DX100BHTR DX100BHTS DX100BHPTR DX100BHPTS only see figures C and D The pre set humidity operation is factory set at approximately 75 Relative Hum...

Page 9: ...on off switch When the fan is switched off the fan continues to operate for the adjustable time delay then goes into automatic mode Pull Cord operation Use the integral pull cord switch When the fan i...

Page 10: ...for details By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe...

Page 11: ...Office UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE England Telephone 44 0 844 372 7761 www xpelair co uk www xpelair co uk int...

Reviews: