background image

English

If wall mounting the fan, you will also need:

•  A 100mm diameter prepared hole.

•  A Simply Silent Wall Kit: 

SSWKWR (92991AW) – Round / White 

SSWKWS (92992AW) – Square / White 

SSWKBR (92993AB) – Round / Brown 

SSWKBS (92994AB) – Square / Brown

If ceiling mounting the fan, you will also need:

•  A 100mm diameter prepared hole.

•  A 100mm diameter prepared hole for the 

external grille (not supplied), ideally positioned 

to allow condensation to run away from the first 

bend in the duct, towards the external grille.

•  Appropriate ancillaries for termination. These 

items are available from Xpelair:

1. 3m flexible ducting Ref: 89663AA. If 

the duct passes through a cold space use 

insulated duct ref: 89847AA.

2. Soffit Grille Ref: 89742AW.

If window mounting the fan, you will also need:

•  SSWIN – Simply Silent Window Kit.  

Ref: 92996AA

Installing the isolating switch  
and cables.

A means for disconnection in all poles 

must be incorporated in the fixed wiring  

 

in accordance with wiring regulations

•  If metal switch boxes are used, earthing 

regulations must be followed.

•  The cross-sectional area of the supply cord 

used should be ranged from 1-1.5mm².

•  DX100BR / DX100BS / DX100BPR / 

DX100BPS – 2 core.

•  DX100BTR / DX100BTS / DX100BHTR* 

/ DX100BHTS* / DX100BHPTR* / 

DX100BHPTS* – 3 core.

  * If wiring to remote switch.

1. Check that the electrical rating shown inside 

the back-plate matches your mains supply.

2. Check there are no buried pipes or cables 

e.g. electricity, gas, water behind the switch 
location (in the wall or above the ceiling). If in 
doubt, seek professional advice.

3. Isolate the mains supply.

4. Lay in the cable from the isolating switch to the 

fan location via the on/off switch (if required).

5. Lay in the cable from the isolating switch to 

the point of connection to the mains supply.

Warning: Do not make any 
connections to the electrical supply 
at this stage.

6. Install the isolating switch and on/off switch 

(if required).

7. Make all connections within the isolating 

switch and the on/off switch (if required).

Wet Rooms: On/Off switch must 
be situated so that it cannot be 
touched by persons making use of 
the bath or shower.

For Australia Only – DX100BR / DX100BS / 
DX100BPR / DX100BPS 

Connection to the 

supply can be made by a flexible 2-core cable 

complete with 3 pin plug for insertion into an 

approved 10A GPO or directly wired through an 

approved 10A wall mounted surface switch with 

at least 3mm clearance between contacts.
For Australia Only –DX100BTR / DX100BTS / 
DX100BHTR / DX100BHTS / DX100BHPTR / 
DX100BHPTS 

These models are permanently 

connected to the supply and operation is 

controlled by a remote switch. They should 

be directly wired to the supply through an 

approved 10A wall mounted surface switch 

with at least 3mm clearance between contacts.
Preparing the Fan for installation.

1.   Remove the front cover by depressing the 

latch on the underside of the cover and 

pulling off the front cover from the bottom 

(See Figure B).

If working above ground floor 
level, safety precautions must be 
observed. 

Mark the position of the back-plate

2.   Hold the back-plate so that the level line 

marked on it is orientated horizontally.

3.   Carefully insert the fan tube into the wall duct.

4.   Mark on the wall the positions of the fixing 

holes in the back-plate.

5.   Remove the back plate from the ducting.

6.   Drill screw holes in these positions if necessary, 

and fit wall plugs and screws as required.

If installing in a ceiling, appropriate 
termination ancillaries are required. 
Follow instructions provided.

Mount the back-plate.

7.   Feed the mains cable through the cable 

entry hole in the back plate to the terminals.

8.   Insert the fan tube of the back-plate into the 

wall duct/ceiling as before.

9.   Fasten the back-plate to the wall/ceiling 

using appropriate fasteners. See figure A.

10.  If using screws, do not over tighten.

Summary of Contents for DX100B

Page 1: ...017AW DX100BTR 92998AW DX100BTS 93018AW DX100BHTR 92999AW DX100BHTS 93019AW DX100BHPTR 93000AW DX100BHPTS 93020AW DX100BPR 93001AW DX100BPS 93002AW Xpelair Simply Silent DX100B Installation and Mainte...

Page 2: ...e electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Installation and Maintenance Instructions English Standard Timer Hu...

Page 3: ...by the integral humidity sensor by using an external on off switch not supplied or by using the integral pull cord switch In automatic mode The built in timer automatically operates the fan for the pr...

Page 4: ...n timer setting Fan switches on at lower level of condensation anti clockwise MORE SENTITIVE RH 50 Fan runs on for a shorter time when the external switch is turned off Fan does not switch on until hi...

Page 5: ...USTOMER CONNECTION TERMINAL DETAIL C SCALE 2 000 OVER RUN TIMER DETAIL B SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED SEE DETAIL A CUSTOMER CONNECTION TERMINAL SE...

Page 6: ...SEE DETAIL E CUSTOMER CONNECTION TERMINAL DETAIL F SCALE 2 000 SET JUMPER TO REQUIRED POSITION FOR SPEED SETTING HIGH SPEED LOW SPEED DETAIL D SCALE 2 000 OVER RUN TIMER HUMIDISTAT DETAIL E SCALE 2 0...

Page 7: ...trical supply at this stage 6 Install the isolating switch and on off switch if required 7 Make all connections within the isolating switch and the on off switch if required Wet Rooms On Off switch mu...

Page 8: ...increase and anti clockwise to decrease see Figure D1 DX100BHTR DX100BHTS DX100BHPTR DX100BHPTS only see figures C and D The pre set humidity operation is factory set at approximately 75 Relative Hum...