Fan Settings
SPEED SETTING
The fans are factory set to low speed, but have
two speed settings for different applications.
Select either high or low speed by connecting
the jumper between the centre and high or low
speed pin on the jumper (see Figure E)
DX150TS / DX150TR Only
• To adjust the over-run period turn the control
(T) clockwise to increase and anti-clockwise
to decrease – see Figure D.
DX150HTS / DX150HTR Only – see figures D and E
• The pre-set humidity operation is factory set
at approximately 75% Relative Humidity (RH),
but can be adjusted between 65% and 85%
RH by control H.
• The over-run timer is factory set at 15 minutes
but can be adjusted from 30 seconds to 30
minutes by control T.
• Turn the controls clockwise to increase RH or
time and anti-clockwise to decrease.
Using the fan
DX150S / DX150R Only
• Operate the fan using the on/off switch (not
supplied). Repeat to switch off.
DX150PS / DX150PR Only
• Operate the fan by pulling and releasing the
cord. Repeat to switch off.
DX150TS / DX150TR Only
• Operate the fan using an on/off switch (not
supplied). When the switch is turned off,
the fan continues to operate for the set time
delay. To adjust the over-run period, turn the
control “T” clockwise to increase and anti-
clockwise to decrease – see Figure F.
DX150HTS / DX150HTR Only
•
Automatic mode
- The fan automatically
adjusts to slow changes in natural humidity
levels without operating the fan. If the
humidity levels increase at a rate slower
than 5% RH in 5 minutes, up to the pre-set
humidity level, the fan will not be triggered
by humidity. This is to prevent nuisance
triggering of the fan. If humidity levels increase
quicker than 5% RH in 5 minutes the fan will
operate. When relative humidity drops the fan
continues to operate for the adjustable time
delay.
•
External operation
- Use the external on/off
switch. When the fan is switched off, the fan
continues to operate for the adjustable time
delay then goes into automatic mode.
All Fans
Re-fit the front cover/baffle assembly by hooking
in the top first, and then swing the cover down
to clip into place.
DX150S/DX150R
DX150PS/DX150PR
DX150TS/DX150TR
DX150HTS/DX150HTR
F
FAN
TERMINALS
FAN
TERMINALS
DOUBLE POLE
ISOLATING SWITCH
DOUBLE POLE
ISOLATING SWITCH
ON/OFF
SWITCH
LAMP
(IF REQUIRED)
FUSE
FUSE
• For fixed wiring circuits the protective fuse for the appliance must not exceed 5A.
• Terminal E can be used as a parking terminal for an earth wire (if required)
English
Summary of Contents for Simply Silent 93070AW
Page 2: ......