background image

Wiring and Setting Up

E

SEE DETAIL A

CUSTOMER 

CONNECTION 

TERMINAL

SHUTTER 

ACTUATOR 

CONNECTIONS

SET JUMPER TO 

REQUIRED POSITION 

FOR SPEED SETTING

LOW 

SPEED

HIGH 

SPEED

DETAIL A

SCALE 2.000

F

N

E

L

N

L

CUSTOMER

 

CONNECTION

TERMINAL

FUSE

SHUTTER

 

ACTUA

TOR

 

CONNECTIONS

FROM SHUTTER 

ACTUATOR

SOLN

Either wire may be installed in either terminal for the shutter actuator to operate

For fixed wiring circuits the protective fuse 
for the appliance must not exceed 5A.

Electrical Connections

English English

Summary of Contents for Simply Silent SSGX150S

Page 1: ...SSGX150S 93195AW SSGX150R 93196AW SSGX150PS 93222AW SSGX150PR 93223AW Xpelair Simply Silent GX150 Window Fan Installation and Maintenance Instructions English ُ ِ َ َ ...

Page 2: ...ing Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user Standard SSGX150S 93195AW SSGX150R 93196AW Pull Cord SSGX150PS 93222AW SSGX150PR 93223AW Installation and Maintenance Instructions English English ...

Page 3: ...he window duct and then feed through the cable access hole in the fan for termination into the customer connection terminal on the fan control board Ensure the cable access is sealed with a suitable sealant to maintain IPX4 rating Where to locate the fan Fan is designed for direct mounting into a window with a 184mm to 190mm hole up to 30mm thick Locate it as high as possible As far away as possib...

Page 4: ...EWS GENTLY TO SECURE DUCT IN WINDOW HOLE NOTE LEVEL LINE AND ORIENTATION DEPRESS COVER LATCH WITH TOOL REMOVE COVER BAFFLE COMPLETE Install Fan Assemble Gasket SECURE FAN TO WINDOW DUCT WITH SCREWS PROVIDED REMOVE PAPER BACKING FROM SELF ADHESIVE GASKET Front cover removal 51 128 English English ...

Page 5: ...OW SPEED HIGH SPEED DETAIL A SCALE 2 000 F N E L N L CUSTOMER CONNECTION TERMINAL FUSE SHUTTER ACTUATOR CONNECTIONS FROM SHUTTER ACTUATOR SOLN Either wire may be installed in either terminal for the shutter actuator to operate For fixed wiring circuits the protective fuse for the appliance must not exceed 5A Electrical Connections English English ...

Page 6: ...ow duct into window ensure level line is horizontal 3 Gently tighten the three clamp screws to secure duct into window See Figure B 4 Route power cable via cutout into window duct Ensure power cable remains near edge of duct If working above ground floor level safety precautions must be observed Fan installation 1 Carefully insert the fan into the window duct 2 Feed the mains cable and shutter act...

Page 7: ...ir Group Limited Exclusions This guarantee does not cover compensation for the loss of the product or consequential loss of any kind Damage or defects to the product arising from incorrect installation or lack of maintenance Transportation costs This guarantee does not affect your statutory rights Technical advice and service Customers outside UK see international below United Kingdom Xpelair have...

Page 8: ...e UK Sales Office and Spares Redring Xpelair Group Ltd Newcombe House Newcombe Way Orton Southgate Peterborough PE2 6SE England Telephone 44 0 844 372 7761 www xpelair co uk www xpelair co uk international FM02118 ISO 9001 2000 ...

Reviews: