Note: The transformer unit should be connected to the

mains supply through a fused double pole isolating switch

maximum 5 amps.

Min 6 inches

Installation Instructions

If working above Ground Floor level, appropriate safety precautions must be observed.

WARNING

EYE PROTECTION MUST BE WORN DURING ALL DRILLING AND CHISELLING OPERATIONS

Safety First

The Heat Recovery Ventilator is a ”SELV” (Safety Extra Low Voltage) ventilator which operates at 12 volts AC. Under no
circumstances must this be connected directly to the mains supply. Damage so caused is not covered by the warranty.
The low voltage used by the ventilator must be provided by the isolating transformer. A typical layout of installation is
shown below.

The Heat Recovery Ventilator can be used in any room which has an outside wall open to fresh air. It is particularly
useful in the bathroom, kitchen or laundry room where high levels of moisture are generated. It can also be used in the
lounge, dining room or any bedroom to provide a fresh air supply to reduce dust-mite, eliminate mould growth or
dampness and condensation and to provide warmed fresh air.

April 2000

These appliances are intended for connection to fixed wiring.

Check that the electrical rating shown on the transformer matches the mains supply.

All installation must be supervised by a qualified Electrician.

Installation and wiring must conform to current IEE Regualtions(UK), local or appropriate regulations 
(other countries)      

The  product must be supplied by a double pole isolating switch with a minimum contact gap of 3mm.

The product is double insulated and does not require earth connection. A parking terminal is provided to 
ensure continuity of external protective wiring only, and when used must comply with the relevant regulations

WARNING

THESE APPLIANCES ARE DOUBLE INSULATED AND DO NOT REQUIRE AN EARTH CONNECTION

If you  have any queries before installing this product or after it has been installed, please contact GDA 
Applied Energy, Customer Services - see back cover. Customers  outside the UK should contact their  
local Xpelair distributor.

Xpelair Heat Recovery Ventilation Range- XHR150PC and XHR150HP 

Xpelair Heat Recovery Unit  have the following features: XHR150PC 

Integral Pull Cord

Heat Recovery Ventilator 

VENTILATOR

Eclipse - Oxplaire  12/4/00  6:51 pm  Page 1

Summary of Contents for XHR150HP

Page 1: ...reduce dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical rating shown on the transformer matches the mains supply All installation must be supervised by a qualified Electrician Installation and wiring must conform to current IEE Regualtions UK local or appro...

Page 2: ...can be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreases the sensitivity fan in boost for shorter time and anti clockwise increases the sensitivity fan in boost for longer time To prevent tampering with the setting after installation the thumbwheel can ...

Page 3: ...tric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensation problems dampness and mould growth are stimulated by high levels of humidity the source of which can be the bath shower room laundry room kitchen or possibly a damp wall Identify an area in the roo...

Page 4: ... masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required length The length should be 4mm greater that the length of the hole x but no less that 254mm otherwise the Heat Exchanger will not fit Carefully mark the tube all round and cut with a hacksaw and fini...

Page 5: ...sive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it outwards and increase it s internal diameter as much as possible This will assist the re entry of the tube Compress the adhesive fully against the wall to hold it in position h Fit the outside cowl to ...

Page 6: ... or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl Measure the distance from the back edge of the wall plate to the other end of the tube The tube should not extend beyond the outside wall finisher Use the PVC weld adhesive to stick the wall plate t...

Page 7: ...uble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screwdriver and No 1 or No 2 pozidrive screwdrivers Masonry drill hammer chisel or core drill equipment if available Mortar to make good the hole if required Decide how you are going to run the wires from...

Page 8: ...own on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trickle speed has been factory set However if it is found that the fan is audible at this setting it is possible to reduce the trickle speed still further Remove the lid of the control box and move the fu...

Page 9: ...s depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise prevents boost operating during darkness A simple test for the correct setting is to trigger the boost feature via the humidity sensor in a darkened room When switching the light on or off the boost sp...

Page 10: ...e and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 8709 000430 By Fax on Techfax 44 0 8709 000530 At the ...

Reviews: