background image

[1]

Installation and Maintenance Instructions

Xpelair C100P

Pull Cord

Xpelair C100T

Timer

Xpelair C100HT

Humidistat, Timer and Pull Cord

Contour Range of Toilet / Bathroom Fans with AC motors

Summary of Contents for Xpelair C100T

Page 1: ... 1 Installation and Maintenance Instructions Xpelair C100P Pull Cord Xpelair C100T Timer Xpelair C100HT Humidistat Timer and Pull Cord Contour Range of Toilet Bathroom Fans with AC motors ...

Page 2: ... 2 B C A D ...

Page 3: ... 3 F E ...

Page 4: ...r appropriate regulations other countries If you have any queries before installing these products or after they have been installed call the Xpelair Technical Hotline 44 0 844 372 7766 Our engineers are there to help you during normal office hours UK only and may be faxed at all other times on 44 0 844 372 7767 Customers outside the UK should contact your local Xpelair distributor Description All...

Page 5: ...Building Regulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates When intended for use in possible chemical corrosive atmospheres consult out Technical Service Department For ove...

Page 6: ...emove the Baffle assembly by removing the screw from the underside of the cover and pulling off from the bottom corners first Remove the electrical cover by removing the 2 screws Mount the fan in the hole If working above ground floor level safety precautions must be observed If installing in a wall or ceiling Mark the position of the backplate 1 Hold the backplate so that the word TOP marked on i...

Page 7: ...te slower than 5 RH in 5 minutes up to the pre set humidity level the fan will not be triggered by humidity This is to prevent nuisance triggering of the fan If humidity levels increase quicker than 5 RH in 5 minutes the fan will operate When relative humidity drops the fan continues to operate for the adjustable time delay Manual mode Use the integral pull cord switch When the fan is switched off...

Page 8: ... of maintenance Transportation costs This guarantee does not affect your statutory rights Technical advice and service Customers outside UK see international below United Kingdom Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to su...