background image

Do’s and Don’ts

D

o read the entire instruction leaflet before commencing installation.

Do install each fan with a means for disconnection in all poles in the fixed wiring.

Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance 
or cleaning.

Guarantee.

UK only:
We, Applied Energy Products Ltd., provide a guarantee against faulty parts and manufacture for a period of 3 years from the date of 
purchase. In the unlikely event of a product breakdown during the guarantee period the product should be returned to the place of 
purchase or to Applied Energy Products Ltd.

Exclusions:

This guarantee does not cover compensation for the loss of the product or consequential loss of any kind.

Damage or defects to the product arising from incorrect installation or lack of maintenance.

Transportation costs.

This guarantee does not affect your statutory rights

Technical advice and service

Customers outside UK - see international below.
United Kingdom

Xpelair have a comprehensive range of services including:

Free technical advice help-desk from Engineers on all aspects of ventilation.

Free design service, quotations and site surveys.

Service and maintenance contracts to suit all requirements.

Please ask for details:

By telephone on Techline: +44 (0) 844 372 7766

By fax on Techfax: +44 (0) 844 372 7767

At the address below

Head Office, UK Sales Office and Spares

Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ England
Telephone: +44 (0) 844 372 7761
Fax: +44 (0) 844 372 7762
Sales/Spares Hotline: +44 (0) 844 372 7750
Sales/Spares Faxline: +44 (0) 844 372 7760
http:\\www.xpelair.co.uk

International.

Guarantee: Contact your local distributor or Xpelair direct for details.

Technical Advice and Service: Contact your local Xpelair distributor.

Part No: 24117AA
(Revision A)

Installation and Maintenance Instructions

Xpelair SL100 / SL150

Standard

Xpelair SL100P / SL150P

Pull Cord

Xpelair SL100T / SL150T

Timer

Xpelair SL100HT / SL150HT

Humidistat, Timer and Pull Cord

Xpelair SL100PIR / SL150PIR

Integral Body Movement Sensor

Toilet / Bathroom 100mm and 150mm AC Slimline Fan Range

Summary of Contents for Xpelair SL150T

Page 1: ...outside UK see international below United Kingdom Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the ...

Page 2: ...ity This is to prevent nuisance triggering of the fan If humidity levels increase quicker than 5 RH in 5 minutes the fan will operate When relative humidity drops the fan continues to operate for the adjustable time delay Manual mode Use the integral pull cord switch When the fan is switched off it goes into automatic mode Light flashes when the fan is operating in manual mode External operation U...

Page 3: ...ole ƒ100mm for SL100 range or ƒ150mm for SL150 range Preparing the fan for installation Remove the front cover by removing the screw from the underside of the cover and pulling off the cover from the bottom corners first Remove the electrical cover by removing the 2 screws Mount the fan in the hole If working above ground floor level safety precautions must be observed If installing in a wall or c...

Page 4: ...or core drill equipment if available Mortar to make good the hole around the ducting FOR SL100 Range If ceiling mounting the fan You will need the use of appropriate ancillaries for termination These items are available from Xpelair 1 WT10 Termination ducting kit 2 FD100 Flexible Ducting 3 XCT100 Condensation Trap FOR SL150 Range If wall mounting the fan you will also need SLWK15 Wall Kit or alter...

Reviews: